3. 30'-54' Roof Instructions

PNEG-1801 Special 30'-54' Diameter High Snow Roof Rafter Instructions

53

Special Rafter Instructions for 54' Diameter High Snow Roof

The 54' diameter high snow roof comes with 18 roof rafter assemblies and 54 purlins that are not included
in the 30° roof manual (PNEG-1092). Install one roof rafter per sidewall sheet. Please refer to the roof
manual for the complete roof assembly details.

NOTE: Each rafter has three (3) sections.

Figure 3AQ

See detail AA

on Page 54

See detail AB

on Page 55

See detail AC

on Page 56

See detail AD

on Page 57

See detail AE

on Page 58

See detail AF

on Pages 59
and 60