beautypg.com

Chapter 7: roof assembly – Grain Systems Tanks PNEG-4072A User Manual

Page 99

background image

Chapter 7: Roof Assembly

NOTE: Ensure that the orientation of the roof panel clip is correct, roof panel holes facing the roof

and the notch in the roof panel clip is facing the right-hand roof rafter.

3. Tighten all hardware to the recommended torque specifications only after the roof panels are

installed. See

Bolt Torque Specifications, page 24

.

Figure 7-23 Roof panel clip

A

Left-hand roof rafter (CTR-0419 and CTR-
0423)

D

1/2 x 1-3/4 in. flange bolt (S-10252)

B

Roof panel clip (CTR-0143)

E

1/2 in. flange nut (S-10253)

C

Right-hand roof rafter (CTR-0419 and CTR-
0423)

After You Finish

Repeat this procedure for the remaining roof panel clips.

Pneg-4072A 72 Ft Diameter 40-Series Bin