beautypg.com

3 post, 66" side draw systems, Viewed from inside of bin) – Grain Systems Bin Accessories PNEG-066 User Manual

Page 8: Viewing inside of typical 29 ring bin, First chute location, Detail "c

background image

8

PNEG-066 2.66" & 4.00" Side Draw Installation

2.66" Side Draw Systems

16'-4"

EXTERNALL

Y

STIFFENED IS 1-1/3" HIGHER

STIFFENER
COLUMN

VIEWING INSIDE OF

TYPICAL 29 RING BIN

NOTE: Unload tube and supports from
rack & pinion not provided by G.S.I.

14"

(35.56 cm)

7th
SIDEWALL
RING

WIND RING INSTALLATION

Tanks that use wind rings require 2-3/4" dia. holes
passing through the side draw chute; with the center
no less than 6" from either end and 4-3/8" from the
sidewall. The wind ring must penetrate through the
chute and form a complete ring. Do not locate wind
ring in 8" space at chute entrance. Field drill stiffeners
for wind ring attachment bracket. (if required.)

3 Post

7"

(17.78 cm)

6th
SIDEWALL
RING

HORIZONTAL
SEAM

STIFFENER COLUMN

STIFFENER

COLUMN

11"

(27.94 cm)

13.5" (34.29 cm)

19"

FIELD CUT
DISCHARGE HOLE
1-1/2" RADIUS
AT CORNERS
(3.80 cm)

4"

(16.16 cm)

(48.26 cm)

18-3/4"

(47.63 cm)

DISCHARGE TUBE INSTALLATION
1.)

Use the bottom 2 holes in the last chute to locate

discharge tube 28" below the 7th horizontal seam. Refer
to Detail "C" for sidewall sheet hole dimensions.

2.)

For proper water shed install plate so upper body sheet

overlaps the plate, as shown in Detail "D".

3.)

Use discharge tube assembly as a template, drill all holes

7/16" diameter.

4.)

Use 2 beads of caulking to seal discharge plate to body

sheets. Use 3/8" bolts & nuts provided to bolt discharge
assembly to body sheets.For all locations where the
sidewall uses 3/8" x 1-1/2" Long Bolts, use the same bolt
to install the discharge tube.

75"

(190.5 cm)

37-1/2"

(95.25 cm)

FIRST CHUTE LOCATION

STIFFENER
COLUMN

DETAIL "C"

(Viewed From Inside Of Bin)

NUMBER OF RINGS

CHUTE LOCATION

IN TANK

HORIZONTAL STARTING LOCATION

1.) LOCATE 1ST CHUTE IN 2ND RING FROM TOP

ALL

2.) TOP BOLT HOLES IN CHUTE TO BE LOCATED

ON 2ND CORRUGATION OF BODY SHEET

11, 14, 17, 20, 23, 26, 29, & 32, 35

3.) CENTER CHUTE 75 INCHES (LEFT TO RIGHT)

FROM 1ST HOLE IN 2ND BODY SHEET

10, 13, 16, 19, 22, 25, 28, & 31,34, 37 3.) CENTER CHUTE 37.500 INCHES (LEFT TO RIGHT)

FROM 1ST HOLE IN 2ND BODY SHEET

12, 15, 18, 21, 24, 27, 30, & 33, 36

3.) CENTER CHUTE OVER VERTICAL SEAM.

These instructions for 90' diameter tanks and smaller. See

PNEG-972 or PNEG-1343 for 105' diameter tank

sidedraw installation instructions.