Pneumatic fill kit, Chapter 13 pneumatic fill kit, Pneumatic fill kit assembly roof panel – Grain Systems Tanks PNEG-257 User Manual

Page 68: Pneumatic fill kit assembly, Roof panel

background image

68

PNEG-257 12', 15', 18' and 21' Bulk Feed Tanks BFT and GHT Series

13. Pneumatic Fill Kit

Pneumatic Fill Kit Assembly

NOTE: Inlet and exhaust parts from roof eave upward supplied with kit.

Figure 13A

Roof Panel

Identical pre-punched roof panels are available from GSI for inlet and outlet sections of pneumatic fill
systems. Extruded lip of the panels provide for weather-tight installation. Caulking placed between angle
rings virtually eliminates all leakage problems. Rubber seal must be utilized at roof cap area to prevent
material “blow by” from pressurized systems.

To install fill kits in roof panels not pre-punched, cut 5-5/8" (143 mm) diameter holes in opposing roof
panels as shown

in Figure 13B

and Figure 13C on Page 69

. Caulk sufficiently to provide weather-tight seal.

Refer to “peak ring seal strip” installation procedure when installing pneumatic fill kits.