PNEG-1859 2.66" Corrugation 135' Diameter Tank with 50 PSF Snow Roof

6. Caulking Details

Caulking Detail for Standard (Non-Laminated) Sheets

Figure 6A Standard and Quad Punched Sidewall Sheets as Viewed from Outside

Apply one strip of caulking near the outside edge of the outer sheet and between the outer two (2) rows
of bolts, refer to

Figure 6A

. A strip of caulking 10" long, should be placed along the horizontal seams.

Before bolting the next ring into place, apply one strip of caulking 10" long on the front of the underlapped
sheet at each joint. Also, a 10" strip of caulking is to be placed along the lower horizontal edge of
lapping sheet at every vertical seam. This will fill the space that occurs between the holes caused by the
overlapping sheets. Use the supplied tube caulk to fill the larger gaps that occur with heavier gauges and
laminated gauges.

See Page 27

for details on caulking of laminated sheets.

Figure 6B Caulking Detail as Viewed from Inside of Bin