Velleman GIK12 User Manual
Page 4
GIK12 / GIK12I
02.12.2010
©Velleman nv
4
•
Flying insects, attracted by the UV light [A], land on the glue board located at the inside of the front
cover, get stuck and die from dehydration.
a. Mounting
•
Determine a proper mounting location. The insect killer should be mounted in a rather dark place
at a height of about 2m (out of reach of children). The device is not suitable to be used in a
garage, stable or similar (semi-outdoor) environment.
Note: a mains outlet is required near the mounting location.
•
Remove the lamp [A] from the socket [B] by gently pulling it out of the socket.
•
Screw the insect killer tightly against a wall using two screws [E]. Make sure the wall is capable
of supporting the weight of the insect killer.
•
Gently reseat the lamp [A] in the socket [B].
•
Hang the front cover over the hooks [F] of the insect killer.
b. Glue board
•
Remove the protective cover of the glue board and slide it with the sticky side facing the UV-
lamp in the front cover.
•
Replace the glue board on a regular basis. Spare glue board: GIK12GB (5 pcs).
c. Switching on/off
•
Connect the included power cable to the power socket [D].
•
Plug the other end of the cable into a suitable mains outlet to switch on the lamp.
•
To switch off the lamp, simply unplug the power cable from the mains.
d. Cleaning the device
•
Unplug the device from the mains.
•
Clean the insect killer regularly with a moist soft cloth. Do not use alcohol, abrasives or solvents.
Do not submerge into any liquid.
•
Make sure no dust accumulates on the UV lamps as this will greatly reduce their effectiveness.
e. replacing lamps and starters
•
When the lamp is worn, it must be replaced with a similar type (see technical specifications).
•
Unplug the device from the mains and remove the front cover.
•
Remove the UV-lamp [A] by gently pulling it out of the socket [B]. Pull straight and away from
the socket.
•
Plug a new UV-lamp into the socket.
•
To replace a starter [C], turn the starter a quarter turn anticlockwise and pull it out of the
socket. Insert a new starter with the same specifications (220-240V~, 4-65W) into the socket
and turn it a quarter turn clockwise to secure it.
•
Place the front cover back and reconnect the device to the mains power outlet.
6. Technical specifications
input voltage
230VAC / 50Hz
effective area
50~60m²
dimensions
325 x 340 x 190mm
weight 3.3kg
lamp
18W 4-pin UV tube (spare lamp: GIK12LAMP)
spare glue board
GIK12GB
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulted from (incorrect) use of this device. For more info
concerning this product, please visit our website www.perel.eu. The information in this
manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.
No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without
the prior written consent of the copyright holder.