beautypg.com

Velleman GIK07 User Manual

Page 4

background image

GIK07-GIK08-GIK09

17.11.2009

©Velleman nv

4

5. Use

Refer to the illustrations on page 2 of this manual.
• Flying insects are attracted by the UV light [D] which is mounted behind a high voltage

electrical grid [B]. When touching the grid, the insects are electrocuted and fall into the
collector [C].

• Place or hang the insect killer in a dry location. Make sure the ON/OFF switch [A] is in the OFF

position and plug the power cord into a suitable mains outlet.

• Switch on the insect killer by moving the ON/OFF switch [A] into the ON position.

6. Cleaning and maintenance

IMPORTANT: Never touch the metal grid with your bare hands! If you need to clean the tray,

follow the safety instructions carefully.

a. Discharging the device before maintenance
• Unplug the device from the mains.

• Use a screwdriver with an insulated handle. Make sure you only hold the screwdriver by the

handle.

• Short-circuit the 2 wires of the inner metal grid by gently touching them simultaneously with the

metal shaft of the screwdriver. A spark may arise. Repeat this manipulation until no more
sparks arise.

b. Cleaning the device
• Make sure the power switch [A] is in the OFF-position and the power plug is disconnected from

the mains outlet before starting any maintenance activity.

• Discharge the device (see a.)

• Slide the insect collector draw [C] out of the device to dispose of dead insects.

• Clean the insect killer regularly with a dry, clean cloth. Do not submerge into any liquid.

• Make sure no dust accumulates on the UV lamps as this will greatly reduce their effectiveness.

• Only use a plastic brush to clean the high-voltage grid. Brush gently to avoid damage.
c. Replacing lamps and starters
• When the lamps are worn, they must be replaced with a similar type (see technical

specifications)

• Make sure the power switch [A] is in the OFF-position and the power plug is disconnected from

the mains outlet before starting any maintenance activity.

• Discharge the device (see a.)

• Remove the two screws on the back of the device (refer to the illustration on page 2, see

arrows).

• Gently pull the outer grid; it will rotate around the screws at the bottom.

• Remove a UV-lamp by gently turning it a quarter turn and pull it upwards out of the sockets.

• Place a new UV-lamp into the socket and turn it a quarter turn to secure it.

• To replace a starter, turn it a quarter turn and pull it out of the socket. Insert a new starter with

the same specifications into the socket and turn it a quarter turn to secure it.

• Close the outer grid and secure the two screws.

7. Technical specifications

GIK07 GIK08 GIK09

input voltage

230VAC / 50Hz

grid voltage

1800-3000V

effective area

30m²

80m²

100m²

dimensions

275 x 105 x 265mm

400 x 105 x 315mm

510 x 105 x 315mm

weight 1.6kg 2.5kg 3kg
lamp

UV-A tube 2 x 6W

(GIK07LAMP)

UV-A tube 2 x 10W

(GIK08LAMP)

UV-A tube 2 x 15W

(GIK09LAMP)