beautypg.com

Overview, Setting up the stations – Velleman WS3080 User Manual

Page 5

background image

WS3080

V. 01 – 21/06/2013

5

©Velleman nv

synchronized instant reception

12 or 24 hour display

perpetual calendar

time zone setting

alarm clock

LED backlight

wall mount or standing free

5.

Overview

Refer to the illustrations on page 2 and 3 of this manual.
A

upper pole

F

side support

B

lower pole

G

rain sensor

C

top support

H solar panel

D

anemometer

I

sensor shelter

E

wind vane + direction sensor

J

thermo-hygrometer (under shelter)

a

MENU button

d

DOWN button ()

b

ENTER button

e

ALARM ON/OFF button(

)

c

UP button ()

f

HISTORY button

1

Weather forecast

10 Outdoor reception signal

2

Barometric pressure

11 Outdoor humidity

3

Barometric trend

12 Outdoor temperature

4

Date

13 Wind direction

5

Memory

14 Wind speed/gust

6

Time

15 UV index

7

Indoor humidity

16 Rainfall

8

Indoor temperature

17 Light intensity

9

transmitter low battery indicator

18 Radio Controlled Clock (RCC) indicator

6.

Setting up the stations

1. Connect the lower pole [B] with the upper pole [A].
2. Place the anemometer [D] on the top support [C] and fix with a bolt and nut.
3. Place the wind vane [E] on the top support [C] and fix with a bolt and nut.
4. Place the top support [C] on top of the upper pole [A] and fix with a bolt and nut.
5. Mount a side support [F] on the pole [A+B] and place the rain sensor [G] on top. Secure it with a screw.
6. Mount the second side support [F] on the pole [A+B].
7. Place the solar panel [H] on top of the shelter [I] and secure it with a bolt and nut.
8. Make all necessary connections:

o

Connect the anemometer [D] to the wind vane [E] phone jacket.

o

Connect the wind vane [E] to the thermo-hygrometer [J] WIND phone jacket (left).

o

Connect the rain sensor to the thermo-hygrometer [J] RAIN phone jacket (right).

9. Insert 2 x AA rechargeable batteries (incl.) into the thermo-hygrometer [J] respecting the polarity as

indicated inside the casing. Only use rechargeable batteries!

10. To ensure DCF reception, immediately insert 3 x AA batteries into the receiver respecting the polarity. Refer

to the section Initialization below for more information on DCF. Note that the receiver is located inside the
thermo-hygrometer

11. Slide the thermo-hygrometer [J] into the shelter [I].
12. Place the thermo-hygrometer [J] on top of the second side support [F] and secure it with a screw.
13. It is strongly recommended to test the station before mounting it outdoors.
14. Wait for the two stations to synchronize. This synchronisation may take a couple of minutes. Do not touch

any button during synchronisation. Once the synchronisation finishes, make sure that all components work
properly.