Control System
Electronic management
Monitor Display Screen
The monitor is a full color, 400 × 234 pixels Liquid Crystal
Display (LCD). A master caution lamp blinks ON and OFF
when one of the critical conditions below occurs:
•
Engine oil pressure low
•
Coolant temperature high
•
Hydraulic oil temperature high
Under normal conditions or the default condition, the monitor
display screen is divided into four areas: clock and throttle
dial, gauge, event display and multi-information display.
Gauge Display
Three analog gauges, fuel level, hydraulic oil temperature
and coolant temperature are displayed in this area.
Electronic Joysticks
Electronic joysticks provide features not possible
with hydraulic pilot valves:
•
Eliminate pilot lines in cab for quieter operation
•
Simple pattern change through the monitor
Operator Gain/Response
This is used to suit the operator preference or application.
•
Quicker for fast response
•
Slower, for more precision
•
Contains three preset settings with 21 available
Pattern Control Changer
The standard hand control pattern changer can be accessed
through the monitor, to utilize either the standard excavator
control pattern (SAE) or Backhoe Loader pattern (BHL).
Alternator
The alternator is 24 volt with 75 amp capacity and is driven
by a serpentine belt off the front pulley. A snorkel pulls cool,
clean air from the outside for increased service life.
Product Link
Product Link is standard on the 374D L. Product Link
transmits diagnostic information from the machine back
to Caterpillar, Cat dealers and customers.