Vishay high power products, Ultrafast soft recovery diode, 150 a fred pt – C&H Technology 150EBU02 User Manual
Page 5

www.vishay.com
For technical questions, contact:
Document Number: 93002
4
Revision: 07-Jul-09
150EBU02
Vishay High Power Products
Ultrafast Soft Recovery Diode,
150 A FRED Pt
TM
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
Fig. 7 - Typical Reverse Recovery Time vs. dI
F
/dt
Fig. 8 - Typical Stored Charge vs. dI
F
/dt
Note
(1)
Formula used: T
C
= T
J
- (Pd + Pd
REV
) x R
thJC
;
Pd = Forward power loss = I
F(AV)
x V
FM
at (I
F(AV)
/D) (see fig. 6);
Pd
REV
= Inverse power loss = V
R1
x I
R
(1 - D); I
R
at V
R1
= 80 % rated V
R
Average Forward Current - I
F
(AV)
(A)
Allowable Case Temperature (°C)
60
80
100
120
140
160
180
0
50
100
150
200
250
DC
Square wave (D = 0.50)
80% Rated Vr applied
see note (1)
Average Power Loss ( Watts )
Average Forward Current - I
F
(AV)
(A)
0
50
100
150
200
250
0
50
100
150
200
250
DC
RMS Limit
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
trr ( ns )
di
F
/dt (A/µs )
10
20
30
40
50
60
70
0
0
0
1
0
0
1
IF = 150A
IF = 75A
Vr = 160V
Tj = 125˚C
Tj = 25˚C
Qrr ( nC )
di
F
/dt (A/µs )
0
100
200
300
400
500
600
700
800
900
0
0
0
1
0
0
1
Vr = 160V
Tj = 125˚C
Tj = 25˚C
IF = 150A
IF = 75A