S-35 – C&H Technology CM530813 User Manual
Page 4

S-35
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
CM530813
Dual SCR POW-R-BLOK™ Modules
130 Amperes/800 Volts
INSTANTANEOUS ON-STATE CURRENT, I
TM
,
(AMPERES)
MAXIMUM
ON-STATE CHARACTERISTICS
10
1
2.4
10
2
10
3
10
4
INSTANTANEOUS ON-STATE VOLTAGE, V
TM
, (VOLTS)
2.0
1.6
1.2
0.8
0.4
T
j
= 125
o
C
CYCLES AT 60 H
Z
MAXIMUM PEAK SURGE (NON-REPETITIVE)
CURRENT, I
TSM
, (AMPERES)
MAXIMUM ALLOWABLE PEAK SURGE
(NON-REPETITIVE) CURRENT
10
1
10
2
10
0
3200
2800
2400
2000
1600
1200
800
400
0
MAXIMUM ALLOWABLE CASE TEMPERATURE
(SINUSOIDAL WAVEFORM)
AVERAGE ON-STATE CURRENT, I
T(AV)
,
(AMPERES)
MAXIMUM ALLOWABLE CASE TEMPERATURE, T
C
, (
o
C)
0
130
360
o
RESISTIVE,
INDUCTIVE
LOAD PER
SINGLE
ELEMENT
120
110
100
90
80
70
60
50
20
40
60
80 100 120 140 160
= 30
o
120
o
60
o
90
o
180
o
MAXIMUM ON-STATE POWER DISSIPATION
(SINUSOIDAL WAVEFORM)
AVERAGE ON-STATE CURRENT, I
T(AV)
,
(AMPERES)
MAXIMUM POWER DISSIPATION, P
AV(MAX)
, (WATTS)
0
0
160
360
o
RESISTIVE, INDUCTIVE LOAD
PER SINGLE ELEMENT
20
40
60
80
100
120
140
20
40
60
80
100 120 140 160
180
o
= 30
o
120
o
60
o
90
o
50
MAXIMUM ALLOWABLE CASE TEMPERATURE
(RECTANGULAR WAVEFORM)
AVERAGE ON-STATE CURRENT, I
T(AV)
,
(AMPERES)
MAXIMUM ALLOWABLE CASE TEMPERATURE, T
C
, (
o
C)
0
60
70
80
90
100
110
120
130
360
o
RESISTIVE, INDUCTIVE
LOAD PER SINGLE
ELEMENT
120
o
270
o
= 30
o
90
o
60
o
DC
40
80
120
160
200
180
o
0
MAXIMUM AVERAGE ON-STATE POWER
DISSIPATION (RECTANGULAR WAVEFORM)
AVERAGE ON-STATE CURRENT, I
T(AV)
,
(AMPERES)
MAXIMUM POWER DISSIPATION, P
AV(MAX)
, (WATTS)
0
360
o
RESISTIVE, INDUCTIVE LOAD
PER SINGLE ELEMENT
40
80
120
160
200
40
80
120
160
200
120
o
180
o
270
o
= 30
o
60
o
90
o
DC
TIME, t, (SECONDS)
TRANSIENT THERMAL IMPEDANCE
CHARACTERISTICS (JUNCTION-TO-CASE)
0
10
-3
0.250
10
-2
10
-1
10
0
TRANSIENT THERMAL IMPEDANCE, Z
(J-C)
(t), (
o
C/WATT)
10
0
10
1
0.225
0.200
0.175
0.150
0.125
0.100
0.075
0.050
0.025
INSTANTANEOUS GATE CURRENT, I
G
, (mA)
TRIGGERING
CHARACTERISTICS
10
1
10
2
10
3
10
4
INSTANTANEOUS GATE VOLTAGE, V
G
, (VOLTS)
10
-1
10
0
10
1
10
2
V
GT
= 3.0V
P
G(AV)
=
3.0W
I
GFM
=
4.0A
I
GT
= 100mA
T
j
= 25
o
C
P
GM
= 10W
V
GDM
= 0.25V
V
GFM
= 10V
MAXIMUM ALLOWABLE CASE TEMPERATURE
(REVERSE PARALLEL CONNECTION)
MAXIMUM ALLOWABLE CASE TEMPERATURE, T
C
, (
o
C)
0
40
200
80 120 160
240 280 300
130
50
360
o
RESISTIVE,
INDUCTIVE LOAD
RMS ON-STATE CURRENT, I
(RMS)
, (AMPERES)
NOTE: THE CURVES INDICATE THE
RELATIONSHIP BETWEEN THE CASE
TEMPERATURE AND THE RMS
ON-STATE CURRENT FOR
EACH MODULE.
= 30
o
120
o
180
o
60
o
90
o
120
110
100
90
80
70
60