Vishay bccomponents – C&H Technology 102 PHR-ST User Manual
Page 11

Document Number: 28371
For technical questions, contact:
www.vishay.com
Revision: 03-May-10
177
101/102 PHR-ST
Aluminum Capacitors
Power High Ripple Current Screw Terminals
Vishay BCcomponents
Table 5
TEST PROCEDURES AND REQUIREMENTS
TEST
PROCEDURE
(quick reference)
REQUIREMENTS
NAME OF TEST
REFERENCE
Endurance
IEC 60384-4/
EN130300
subclause 4.13
T
amb
= 85 °C; U
R
applied;
2000 hours
U
R
≤ 100 V; ΔC/C: ± 15 %
U
R
> 100 V; ΔC/C: ± 10 %
tan
δ ≤ 1.3 x spec. limit
Z
≤ 2 x spec. limit
IL5
≤ spec. limit
Useful life
CECC 30301
subclause 1.8.1
T
amb
= 85 x C; U
R
and I
R
applied;
101 series:
Case Ø D
≤ 50: 10 000 hours
Case Ø D
≥ 65: 15 000 hours
102 series:
10 000 hours
U
R
≤ 100 V; ΔC/C: ± 45 %
U
R
> 100 V; ΔC/C: ± 30 %
tan
δ ≤ 3 x spec. limit
Z
≤ 3 x spec. limit
I
L5
≤ spec. limit
No short or open circuit,
No visible damage
Total failure percentage:
U
R
≤ 100 V: ≤ 1 %;
U
R
> 100 V: ≤ 3 %
Shelf life
(storage at
high temperature)
IEC 60384-4/
EN130300
subclause 4.17
T
amb
= 85 x C; no voltage applied;
500 hours
After test: U
R
to be applied for 30 minutes,
24 hours to 48 hours before measurement
ΔC/C: ± 10 %
tan
δ ≤ 1.2 x spec. limit
I
L5
≤ 2 x spec. limit