CM100DU-34KA
Dual IGBTMOD™ KA-Series Module
100 Amperes/1700 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
4
TIME, (s)
NORMALIZED TRANSIENT THERMAL IMPEDANCE, Z
th(
j-
c
)
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(IGBT)
10
1
10
-5
10
-4
10
-3
10
0
10
-1
10
-2
10
-3
10
-3
10
-2
10
-1
10
0
10
1
Single Pulse
T
C
= 25
°
C
Per Unit Base = R
th(j-c)
= 0.14
°
C/W
Z
th
= R
th
• (NORMALIZED VALUE)
10
-1
10
-2
10
-3
TIME, (s)
NORMALIZED TRANSIENT THERMAL IMPEDANCE, Z
th(
j-
c
)
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(FWDi)
10
1
10
-5
10
-4
10
-3
10
0
10
-1
10
-2
10
-3
10
-3
10
-2
10
-1
10
0
10
1
Single Pulse
T
C
= 25
°
C
Per Unit Base = R
th(j-c)
= 0.24
°
C/W
Z
th
= R
th
• (NORMALIZED VALUE)
10
-1
10
-2
10
-3
GATE CHARGE, Q
G
, (nC)
GATE-EMITTER VOLTAGE, V
GE
, (VOLTS)
GATE CHARGE, V
GE
20
0
100
200
300
16
12
8
4
0
400
600
500
V
CC
= 1000V
V
CC
= 800V
I
C
= 100A
COLLECTOR CURRENT, I
C
, (AMPERES)
10
4
10
1
10
2
10
3
10
3
10
2
10
1
t
r
SWITCHING TIME, (ns)
HALF-BRIDGE
SWITCHING CHARACTERISTICS
(TYPICAL)
t
d(on)
t
d(off)
V
CC
= 1000V
V
GE
=
±
15V
R
G
= 3.1
Ω
T
j
= 125
°
C
Inductive Load
t
f
REVERSE RECOVERY CURRENT, I
rr
, (AMPERES)
EMITTER CURRENT, I
E
, (AMPERES)
REVERSE RECOVERY TIME, t
rr
, (ns)
10
3
10
1
10
2
10
3
10
2
10
1
t
rr
I
rr
10
3
10
2
10
1
V
CC
= 1000V
V
GE
=
±
15V
R
G
= 3.1
Ω
T
j
= 25
°
C
Inductive Load
REVERSE RECOVERY CHARACTERISTICS