C&H Technology PS21765 User Manual
Page 4
PS21765
Intellimod™ Module
Dual-In-Line Intelligent Power Module
20 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
Rev. 07/07
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage
V
CE(sat)
V
D
= V
DB
= 15V, I
C
= 20A, V
IN
= 5V, T
j
= 25°C
—
1.60
2.10
Volts
V
D
= V
DB
= 15V, I
C
= 20A, V
IN
= 5V, T
j
= 125°C
—
1.70
2.20
Volts
Diode Forward Voltage
V
EC
-I
C
= 20A, V
IN
= 0V
—
1.50
2.00
Volts
Inductive Load Switching Times
t
on
0.70
1.30
1.90
µS
t
rr
V
CC
= 300V, V
D
= V
DB
= 15V,
—
0.30
—
µS
t
C(on)
I
C
= 20A, T
j
= 125°C,
—
0.50
0.80
µS
t
off
V
IN
= 0 – 5V, Inductive Load
—
1.30
1.90
µS
t
C(off)
—
0.40
0.60
µS
Collector Cutoff Current
I
CES
V
CE
= V
CES
, T
j
= 25°C
—
—
1.0
mA
V
CE
= V
CES
, T
j
= 125°C
—
—
10
mA
Control Sector
Circuit Current I
D
V
IN
= 5V
Total of V
P1
-V
NC
, V
N1
-V
NC
—
—
7.00
mA
V
D
= V
DB
= 15V
V
UFB
-U, V
VFB
-V, V
WFB
-W
—
—
0.55
mA
V
IN
= 0V
Total of V
P1
-V
NC
, V
N1
-V
NC
—
—
7.00
mA
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
—
—
0.55
mA
Fault Output Voltage
V
FOH
V
SC
= 0V, F
O
Terminal Pull-up to 5V by 10k
Ω
4.9
—
—
Volts
V
FOL
V
SC
= 1V, I
FO
= 1mA
—
—
0.95
Volts
Short Circuit Trip Level*
V
SC(ref)
V
D
= 15V
0.43
0.48
0.53
Volts
Input Current
I
IN
V
IN
= 5V
1.0
1.5
2.0
mA
Supply Circuit Under-voltage
UV
DBt
Trip Level, T
j
≤ 125°C
10.0
—
12.0
Volts
Protection
UV
DBr
Reset Level, T
j
≤ 125°C
10.5
—
12.5
Volts
UV
Dt
Trip Level, T
j
≤ 125°C
10.3
—
12.5
Volts
UV
Dr
Reset Level, T
j
≤ 125°C
10.8
—
13.0
Volts
Fault Output Pulse Width**
t
FO
C
FO
= 22nF
1.0
1.8
—
ms
ON Threshold Voltage
V
th(on)
Applied between
—
2.3
2.6
Volts
OFF Threshold Voltage
V
th(off)
U
P
, V
P
, W
P
-V
NC,
0.8
1.4
—
Volts
ON/OFF Threshold Hysteresis Voltage
V
th(hys)
U
N
, V
N
, W
N
-V
NC
0.5
0.9
—
Volts
* Short Circuit protection is only for the lower-arms. Please select the external shunt resistance such that the S
C
trip level is less than 1.7 times the current rating.
**Fault signal is output when the low-arms short circuit or control supply under-voltage protective function works. The fault output pulse-width, t
FO
, depends on the capacitance of C
FO
according to the following approximate equation: C
FO
= 12.2 x 10
-6
x t
FO