C&H Technology TAK7--12 User Manual
Page 3

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
Phase Control SCR
www.pwrx.com
1200 Amperes Average
4400 Volts
Revision Date: 03/26/2010
TAK7
1200A
®
Absolute Maximum Ratings
Characteristics Symbol
Units
Non-Repetitive Transient Peak Reverse Blocking Voltage
V
RSM
V
RRM
+ 100V
Volts
RMS On-State Current, T
C
= 82°C
I
T(RMS)
1700 Amperes
Average Current 180° Sine Wave, T
C
= 82°C
I
T(AV)
1200
Amperes
RMS On-State Current, T
C
= 55°C
I
T(RMS)
Amperes
Average Current 180° Sine Wave, T
C
= 55°C
I
T(AV)
960
Amperes
Peak One Cycle Surge On-State Current (Non-Repetitive) 60 Hz
I
TSM
40,000
Amperes
Peak One Cycle Surge On-State Current (Non-Repetitive) 50 Hz
I
TSM
36,500
Amperes
Critical Rate-of-rise of On-State Current (Non-Repetitive)
di/dt
400
A/μsec
Critical Rate-of-rise of On-State Current (Repetitive)
di/dt
150
A/μsec
I
2
t (for Fusing) for One Cycle, 60 Hz
I
2
t
6.67 X 10
6
A
2
sec
Peak Gate Power Dissipation
P
GM
16
Watts
Average Gate Power Dissipation
P
G(av)
3
Watts
Operating Temperature
T
J
-40 to +125
°C
Storage Temperature
T
stg
-40 to +150
°C
Approximate Weight
2.2
lb
1000
g
Mounting Force
9000 to 11000
lb.
4100 to 5000
kg.
Information presented is based upon manufacturers testing and projected capabilities.
This information is subject to change without notice.
The manufacturer makes no claim as to the suitability of use, reliability, capability,
or future availability of this product.