C&H Technology PS22053 User Manual
Page 4
PS22053
Intellimod™ Module
Dual-In-Line Intelligent Power Module
10 Amperes/1200 Volts
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
3
Rev. 10/05
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage
V
CE(sat)
I
C
= 10A, T
j
= 25°C, V
D
= V
DB
= 15V, V
IN
= 5V
—
2.7
3.4
Volts
I
C
= 10A, T
j
= 125°C, V
D
= V
DB
= 15V, V
IN
= 5V
—
2.5
3.2
Volts
Diode Forward Voltage
V
EC
-I
C
= 10A, V
IN
= 0V
—
2.5
3.0
Volts
Inductive Load Switching Times
t
on
0.8
1.5
2.2
µs
t
rr
V
CC
= 600V, V
D
= V
DB
= 15V,
—
0.2
—
µs
t
C(on)
I
C
= 10A, T
j
= 125°C, V
IN
= 0 ⇔ 5V,
—
0.4
0.7
µs
t
off
Inductive Load (Upper-Lower Arm)
—
2.8
3.8
µs
t
C(off)
—
0.4
0.7
µs
Collector-Emitter Cutoff Current
I
CES
V
CE
= V
CES
, T
j
= 25°C
—
—
1.0
mA
V
CE
= V
CES
, T
j
= 125°C
—
—
10
mA
Control Sector
Circuit Current I
D
V
IN
= 5V
Total of V
P1
-V
PC
, V
N1
-V
NC
—
—
3.70
mA
V
D
= V
DB
= 15V
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
—
—
1.30
mA
V
IN
= 0V
Total of V
P1
-V
PC
, V
N1
-V
NC
—
—
3.50
mA
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
—
—
1.30
mA
Fault Output Voltage
V
FOH
V
SC
= 0V, F
O
Terminal Pull-up to 5V by 10kΩ
4.9
—
—
Volts
V
FOL
V
SC
= 1V, I
FO
= 1mA
—
—
1.10
Volts
Input Current
I
IN
V
IN
= 5V
0.70
1.5
2.00
mA
Short Circuit Trip Level*
V
SC(ref)
V
D
= 15V
0.43
0.48
0.53
Volts
Supply Circuit Under-voltage
UV
DBt
Trip Level, T
j
≤ 125°C
10.0
—
12.0
Volts
UV
DBr
Reset Level, T
j
≤ 125°C
10.5
—
12.5
Volts
UV
Dt
Trip Level, T
j
≤ 125°C
10.3
—
12.5
Volts
UV
Dr
Reset Level, T
j
≤ 125°C
10.8
—
13.0
Volts
Fault Output Pulse Width**
t
FO
C
FO
= 22nF
1.6
2.4
—
ms
ON Threshold Voltage
V
th(on)
Applied between U
P
, V
P
, W
P
-V
PC,
2.5
3.0
4.2
Volts
OFF Threshold Voltage
V
th(off)
U
N
, V
N
, W
N
-V
NC
0.8
1.4
2.0
Volts
* Short Circuit protection is functioning only for N-side IGBTs. Please select the value of the external shunt resistance such that the SC trip level is less than 1.7 times the current rating.
**Fault output is asserted when the lower arms short circuit or control supply under-voltage protection function operates. The fault output pulse-width t
FO
depends on the capacitance value
of C
FO
according to the following approximate equation: C
FO
= (9.3 x 10
-6
) x t
FO
{F} .