30 mm (1.180 in)
15 mm (0.590 in)
0
-15 mm (- 0.590 in)
- 30 mm (- 1.180 in)
1,0 m (3.280 ft)
10 m (32.80 ft)
Fig. 40: Deviation VEGAPULS 61 with plastic horn antenna and increased sensitivity
Influence of the ambient temperature to the sensor electronics
7
)
A
verage temperature coefficient of the zero
signal (temperature error)
0.03 %/10 K
Ambient conditions
A
mbient, storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
V
essel pressure
-
E
ncapsulated antenna system
-100 … 300
kPa/-1 … 3 bar (-14.5 … 43.5 psi)
-
P
lastic horn antenna
-100 … 200
kPa/-1 … 2 bar (-14.5 … 29.0 psig)
P
rocess temperature (measured on the
process fitting)
-40 … +80 °C (-40 … +176 °F)
V
ibration resistance
8)
-
E
ncapsulated antenna system
mechanical vibrations up to 4 g in the frequency
range 5 … 200 Hz
-
P
lastic horn antenna with compression
or adapter flange
mechanical vibrations up to 2 g in the frequency
range 5 … 200 Hz
-
P
lastic horn antenna with mounting strap
mechanical vibrations up to 1 g in the frequency
range 5 … 200 Hz
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
C
able entry/plug
9)
-
S
ingle chamber housing
l
1
x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5
7)
R
elating to the nominal measuring range, in the temperature range
-40 … +80 °C .
8)
T
ested according to the guidelines of German Lloyd, GL directive 2.
9)
D
epending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
VEGAPULS
61 • 4 … 20
mA/HART two-wire
59
10 S
upplement
28434
-EN
-100426