ca. 10 mm

Fig. 10: Recommended socket mounting

I

f the reflective properties of the medium are good, you can mount

VEGAPULS

61

on sockets which are higher than the length of the

antenna. You will find recommended values for socket heights in the
following illustration. The socket end should be smooth and burr-free, if
possible also rounded. After installation you must carry out a false
echo storage.

d

h

d

h

1½"
50 mm/2"
80 mm/3"
100 mm/4"
150 mm/6"

200 mm
250 mm
300 mm
500 mm
800 mm

Fig. 11: Deviating socket dimensions

I

n liquids, align the sensor as vertical as possible to the product

surface to achieve optimum measuring results.