VEGA POINTRAC 31 Foundation Fieldbus User Manual
Page 48
48
11 Supplement
POINTRAC 31 • Foundation Fieldbus
41779-EN-131119
FF descriptor
Rel. In-
dex
Description
Unit
FF_VOLUMETRIC_
FLOW_UNIT
22
Selected unit code for “FF_VOLUMETRIC_FLOW” -
FF_WEIGHT
23
Weight on belt
FF_WEIGHT_UNIT
FF_WEIGHT_UNIT
24
Selected unit code for “FF_WEIGHT”
-
FF_BELT_SPEED
25
Belt speed
FF_BELT_SPEED_
UNIT
FF_BELT_SPEED_
UNIT
26
Selected unit code for “FF_BELT_SPEED”
-
FF_ELECTRONIC_
TEMPERATURE
27
Electronics temperature
FF_ELECTRONIC_
TEMPERATURE_UNIT
FF_ELECTRONIC_
TEMPERATURE_UNIT
28
Selected unit code for “FF_ELECTRONIC_TEM-
PERATURE”
-
FF_COUNT_RATE
29
Count rate
FF_COUNT_RATE_
UNIT
FF_COUNT_RATE_
UNIT
30
Selected unit code for “FF_COUNT_RATE”
-
DEVICE_TAG
31
Tagname
-
DEVICE_NAME
32
Device type
-
DEVICE_STATE
33
Error code
-
PEAK_MEAS_VAL_MIN 34
Pulse rate (min.)
-
PEAK_MEAS_VAL_
MAX
35
Pulse rate (max.)
-
PEAK_TEMP_VAL_MIN 36
Electronics temperature (min.)
-
PEAK_TEMP_VAL_
MAX
37
Electronics temperature (max.)
-
APPLICATION_TYPE_
SEL
38
Selected application
-
TEMP_COMP_UNIT
39
Selected unit code for process temperature
-
DELTA_I
40
Calculated percent delta I
-
GAUGE_TEMPERA-
TURE
41
Electronics temperature
-
DECAY_COMPENSA-
TION_FACTOR
42
Factor for the decay compensation
-
PMT_VOLTAGE_CALI-
BRATION
43
Photomultiplier voltage on delivery
-
CORRELATION_CO-
EFF
44
Correlation coefficient for linearizer table
-
ERROR_TEXT
45
Error text
-
PMT_VOLTAGE_AC-
TUAL
46
Current photomultiplier voltage
-
STANDARDIZATION_
FACTOR
47
Factor for the real value correction
-
SERIALNUMBER
48
Serial number
-