2 supplementary information foundation fieldbus – VEGA POINTRAC 31 Foundation Fieldbus User Manual
Page 46
46
11 Supplement
POINTRAC 31 • Foundation Fieldbus
41779-EN-131119
Electrical protective measures
Protection, depending on housing ver-
sion
IP 66/IP 67
4)
Overvoltage category
III
Protection class
I
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments must be carefully noted.
They are part of the delivery or can be do
w
11.2 Supplementary information Foundation Fieldbus
The following table gives you an overview of the instrument versions and the corresponding device
descriptions, the electrical characteristics of the bus system as well as the applied function blocks.
Revisions Data
DD-Revision
Rev_01
CFF-File
010101.cff
Device Revision
0101.ffo
0101.sym
Cff-Revision
xx xx 01
Device software revision
> 1.5.0
ITK (Interoperability Test Kit) Number
6.0.1
Electricial Characteristics
Physicial Layer Type
Low-power signaling, bus-pow-
ered, FISCO I.S.
Input Impedance
> 3000 Ohms between 7.8 KHz -
39 KHz
Unbalanced Capacitance
< 250 pF to ground from either in-
put terminal
Output Amplitude
0.8 V P-P
Electrical Connection
4 Wire
Polarity Insensitive
Yes
Max. Current Load
10 mA
Device minimum operating voltage
9 V
Transmitter Function Blocks
Resource Block (RB)
1
Transducer Block (TB)
1
Standard Block (AI)
3
Execution Time
30 ms
Diagnostics
Standard
Yes
Advanced
Yes
Performance
No
Function Blocks Instantiable
No
4)
A suitable cable is the prerequisite for maintaining the protection rating.