VEGA VEGABAR 83 Profibus PA - Operating Instructions User Manual
Page 71
71
11 Supplement
VEGABAR 83 • Profibus PA
45037-EN-131107
Interface to the slave sensor
Data transmission
digital (I²C-Bus)
Configuration, connection cable
4-wire, screened
Cable length max.
25 m
Integrated clock
Date format
Day.Month.Year
Time format
12 h/24 h
Time zone Ex factory
CET
Rate deviation max.
10.5 min/year
Measurement electronics temerature
Resolution
1 °C (1.8 °F)
Accuracy
±1 °C (1.8 °F)
Voltage supply
Operating voltage
Ʋ Non-Ex, Ex-d instrument
9 … 32 V DC
Ʋ EEx-ia instrument - Power supply
FISCO model
9 … 17.5 V DC
Ʋ EEx-ia instrument - Power supply
ENTITY model
9 … 24 V DC
Number of sensors per DP/PA segment coupler, max.
Ʋ Non-Ex
32
Ʋ Ex
10
Potential connections in the instrument
Electronics
Not non-floating
Ground terminal
Galvanically connected with the process fitting
Electrical protective measures
Housing material
Version
IP-protection class
NEMA protection
Plastic
Single chamber
IP 66/IP 67
NEMA 4X/6P
Double chamber
IP 66/IP 67
NEMA 4X
Aluminium
Single chamber
IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)
NEMA 4X/6P
-
Double chamber
IP 66/IP 67
IP 66/IP 68 (0.2 bar)
NEMA 4X
NEMA 4X
Stainless steel, electro-
polished
Single chamber
Single chamber
IP 69K
IP 66/IP 68 (0.2 bar)
-
NEMA 4X/6P