beautypg.com

VEGA VEGABAR 83 Modbus and Levelmaster protocol - Operating Instructions User Manual

Page 60

background image

60

10 Supplement

VEGABAR 83 • Modbus and Levelmaster protocol

46295-EN-131107

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

Gauge pressure
0 … +0.15 psig

+225 psig

0 … +5 psig

+375 psig

-11.60 psig

0 … +15 psig

+525 psig

-14.5 psig

0 … +30 psig

+600 psig

-14.5 psig

0 … +150 psig

+1350 psig

-14.5 psig

0 … +300 psig

+1500 psig

-14.5 psig

-14.5 … 0 psig

+500 psig

-14.5 psig

-14.5 … +20 psig

+580 psig

-14.5 psig

-14.5 … +150 psig

+1480 psig

-14.5 psig

-14.5 … +300 psig

+1575 psig

-14.5 psig

-0.7 … +0.7 psig

+225 psig

-14.5 psig

-3 … +3 psig

+290 psi

-14.5 psig

-7 … +7 psig

+510 psig

-14.5 psig

Absolute pressure
0 … 1.5 psi

225 psi

0 psi

0 … 5 psi

435 psi

0 psi

0 … 15 psi

510 psi

0 psi

0 … 30 psi

725 psi

0 psi

0 … 150 psi

1300 psi

0 psi

0 … 300 psi

1900 psi

0 psi

Output variable
Output

Ʋ Physical layer

Digital output signal according to standard EIA-485

Ʋ Bus specifications

Modbus Application Protocol V1.1b, Modbus over serial

line V1.02

Ʋ Data protocols

Modbus RTU, Modbus ASCII, Levelmaster

Max. transmission rate

19.2 Kbit/s

Dynamic behaviour output
Run-up time approx.

10 s

Dynamic characteristics, depending on medium, temperature and, if applicable, chemical seal