3 Product description

VEGAPULS 66 standpipe version • Modbus and Levelmaster protocol

41367-EN-121011

Measurement in a standpipe is not recommended for extremely

adhesive products.
The instrument can be used with products with an ε

r

value ≥1.8. The

actually achievable value depends on the measuring conditions, the

antenna system, the standpipe or bypass.

The antenna of the radar sensor emits short radar pulses with a

duration of approx. 1 ns. These pulses are reflected by the product

and received by the antenna as echoes. The transit time of the radar

pulses from emission to reception is proportional to the distance and

hence to the level. The determined level is converted into an appropri-

ate output signal and outputted as measured value.

3.3 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

according to DIN EN 24180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.

Transport must be carried out under consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause

damage to the device.

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

Up to the time of installation, the packages must be left closed and

stored according to the orientation and storage markings on the

outside.
Unless otherwise indicated, the packages must be stored only under

the following conditions:

Not in the open

Dry and dust free

Not exposed to corrosive media

Protected against solar radiation

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Relative humidity 20 … 85 %

3.4 Accessories and replacement parts

The indicating and adjustment module PLICSCOM is used for meas-

ured value indication, adjustment and diagnosis. It can be inserted

into the sensor and removed at any time.

Functional principle

Packaging

Transport

Transport inspection

Storage

Storage and transport

temperature

Indicating and adjust-

ment module