4 Mounting

VEGABAR 81 • Slave sensor for electronic differential pressure

45049-EN-131011

4.4 Level measurement

The master/slave combination is suitable for level measurement in a

pressurized vessel
Keep the following in mind when setting up the measuring system:

Mount the master sensor below the min. level

Do not mount the master sensor close to the filling stream or

emptying area

Mount the master sensor so that it is protected against pressure

shocks from the stirrer

Mount the slave sensor above the max. level

1

2

Fig. 9: Measurement setup, level measurement in pressurized vessel
1 VEGABAR 81

1 VEGABAR 81 - Slave sensor

4.5 Differential pressure measurement

The master/slave combination is suitable for differential pressure

measurement
Take note of the following instructions for the measurement setup, for

example in gases:

Mount the instruments above the measuring point

Possible condensation can then drain off into the process line.

Measurement setup

Measurement setup