5 parameter adjustment - point level detection – VEGA FIBERTRAC 31 Foundation Fieldbus User Manual
Page 41
41
6 Set up with the display and adjustment module
FIBERTRAC 31 • Foundation Fieldbus
41780-EN-131119
This menu item enables adaptation of the sensor to the requested ap-
plication. You can choose between the following applications: "Level",
"Point level" or "Summation Slave".
In this menu item you can activate the function of the current output.
When the output is activated, the instrument remains in its function as
a Slave, but the 4 … 20 mA output of the FIBERTRAC 31 can be also
used als single instrument.
When the output is active, the instrument has the complete function-
ality of a level measuring instrument. In this case, continue reading
under "Parameter adjustment/Level measurement".
With this menu item you safeguard the sensor parameters against
unauthorized or unintentional modifications.
This menu item is described in the operating instructions manual
"Display and adjustment module".
6.5 Parameter adjustment - Point level detection
The instrument is adapted to the application conditions via the pa-
rameter adjustment. The parameter adjustment is carried out with an
adjustment menu.
Information:
In this operating instructions manual, the instrument-specific param-
eters are described. Further general parameters are described in the
operating instructions manual "Display and adjustment module".
Caution:
During the first setup or after an instrument reset the instrument starts
with preset standard values. These value are not suitable for your ap-
plication and must be replaced by real values.
Carry out a setup in the sequence described in the following.
The main menu is divided into five sections with the following func-
tions:
Setup: Settings, e.g. for measurement loop name, isotope, applica-
tion, background radiation, adjustment, signal output
Display: Settings, for example language, measured value display
Setup - Outputs
Lock setup - adjustment
Instrument start
Main menu