11 Supplement

VEGABAR 86 • 4 … 20 mA/HART

45039-EN-131010

Ʋ Max. length

180 m (590.5 ft)

Ʋ Min. bending radius at 25 °C/77 °F

25 mm (0.985 in)

Ʋ Diameter approx.

8 mm (0.315 in)

Ʋ Colour

Blue

Cable entry/plug

3)

Ʋ External housing

– 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x

blind plug M20 x 1.5

or:

– 1␣x plug (depending on the version), 1␣x blind stopper

M20␣x␣1.5

Spring-loaded terminals for wire cross-

section up to

2.5 mm² (AWG 14)

Display and adjustment module
Display element

Display with backlight

Measured value indication

Ʋ Number of digits

5

Ʋ Size of digits

W x H = 7 x 13 mm

Adjustment elements

4 keys

Protection rating

Ʋ unassembled

IP 20

Ʋ mounted into the housing without

cover

IP 40

Materials

Ʋ Housing

ABS

Ʋ Inspection window

Polyester foil

Interface to the external display and adjustment unit
Data transmission

digital (I²C-Bus)

Configuration, connection cable

4-wire, screened

Cable length max.

Ʋ Sensors with signal output

4 … 20 mA, 4 … 20 mA/HART

50 m

Ʋ Sensors with signal output Profibus

PA, Foundation Fieldbus

25 m

Interface to the slave sensor
Data transmission

digital (I²C-Bus)

Configuration, connection cable

4-wire, screened

Cable length max.

25 m

Integrated clock
Date format

Day.Month.Year