VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire User Manual
Page 20
20
4 Mounting
VEGAPULS 61 • 4 … 20 mA/HART - two-wire
36499-EN-121011
The socket piece should be dimensioned in such a way that the an-
tenna end protrudes at least 10 mm (0.4 in) out of the socket.
ca
. 10 mm
Fig. 15: Recommended socket mounting
If the reflective properties of the medium are good, you can mount
VEGAPULS 61 on sockets which are higher than the length of the
antenna. You will find recommended values for socket heights in the
following illustration. The socket end should be smooth and burr-free,
if possible also rounded. After installation you must carry out a false
echo storage.
d
h
d
h
1½"
50 mm/2"
80 mm/3"
100 mm/4"
150 mm/6"
200 mm
250 mm
300 mm
500 mm
800 mm
Fig. 16: Deviating socket dimensions
Align the sensor in liquids as vertical as possible to the product sur-
face to achieve optimum measurement.
Fig. 17: Alignment in liquids
The mounting location of the radar sensor should be a place where no
other equipment or fixtures cross the path of the microwave signals.
Vessel installations, such as e.g. ladders, limit switches, heating spi-
rals, struts, etc., can cause false echoes and impair the useful echo.
Socket with encapsulated
antenna system
Sensor orientation
Vessel installations