beautypg.com

Group f, 3 planning instructions for isolating systems – VEGA VEGADIF 65 Chemical seal CSB User Manual

Page 9

background image

9

3 Planning instructions for isolating systems

Chemical seal CSB • for VEGADIF 65

36133-EN-130417

– EN/DIN flange DN 100 PN 10-16 B1, 316L

– EN/DIN flange DN 100 PN 25-40 B1, AISI 316L

– DIN 11851 DN 80 PN 25, 316L

– Cell DN 80 PN 16-400, 316L

– Cell DN 100 PN 16-400, 316L

– Cell 3" 150-2500 lbs, 316L

0

1

2

3

4

5

6

7

8

9

10

–40

–20

0

20

40

60

80

Ambient

temperature

[°C

]

Capillary length [m]

Group C

permitted

operating range

Fig. 4: Permissible ambient temperature range depending on the capillary

length for chemical seals of group C

Group D

– ANSI flange 3" 150 lbs RF, 316/316L

– ANSI flange 3" 300 lbs RF, 316/316L

– Cell 3" 150-2500 lbs, 316L

0

1

2

3

4

5

6

7

8

9

10

–40

–20

0

20

40

60

80

Ambient

temperature

[°C

]

Capillary length [m]

Group D

permitted

operating range

Fig. 5: Permissible ambient temperature range depending on the capillary

length for chemical seals of group D

Group E

– ANSI flange 3" 150 lbs RF, 316/316L, extension: 2"/4"/6"/8"

0

1

2

3

4

5

6

7

8

9

10

–40

–20

0

20

40

60

80

Ambient

temperature

[°C

]

Capillary length [m]

Group E

permitted

operating range

Fig. 6: Permissible ambient temperature range depending on the capillary

length for chemical seals of group E

Group F