22

5 Connecting to the bus system

VEGAPULS 65 • Profibus PA

36517-EN-121011

1

1

5

0

0

5

1

6

2

7

3

8

4

9

0

5

1

6

2

7

3

8

4

9

1

0

1

6 7 8

Bus

2
3

1

2

+

( )

(-)

Fig. 15: Electronics compartment, double chamber housing
1 Internal connection to the connection compartment

2 Contact pins for the indicating and adjustment module or interface adapter

3 Selection switch for bus address

Information:

The connection of an external indicating and adjustment unit is not

possible with this double chamber housing.

+

Bus

2

3

1

2

( )

(-)

1

Fig. 16: Connection compartment, double chamber housing
1 Voltage supply, signal output

2 For indicating and adjustment module or interface adapter

3 Ground terminal for connection of the cable screen

1

Bus

USB

Status

Test

SIM-Card

1

2

+

( )

(-)

Fig. 17: CConnection of the voltage supply of the radio module
1 Voltage supply

You can find detailed information for connection in the supplementary

instructions "PLICSMOBILE GSM/GPRS radio module".

Electronics compartment

Connection compartment

Radio module PLICSMO-

BILE integrated in the

connection compartment