Vegabar 67, flange connection – VEGA VEGABAR 67 Profibus PA User Manual
Page 68
68
10 Supplement
VEGABAR 67 • Profibus PA
36743-EN-130321
VEGABAR 67, flange connection
DN PN
D
k
b
FA
25
40
115
18
85
EA
40
40
150
18
110
FB
50 40
165
20
125
d2
4xø14
4xø18
4xø18
d4
68
88
102
f
2
3
3
FE
80 40
200
24
160
8xø18
138
3
FC
32
40
140
18
100
4xø18
78
2
FM 150 16
285
22
240
8xø22
162
3
FK
100 16
220
20
180
8xø18
158
3
mm
inch
1
2
1
2
2
43
/
64
"
3
15
/
32
"
4
1
/
64
"
5
7
/
16
"
6
3
/
8
"
3
5
/
64
"
5
/
64
"
5
/
64
"
1
/
8
"
1
/
8
"
1
/
8
"
1
/
8
"
4xø
35
/
64
"
4xø
45
/
64
"
4xø
45
/
64
"
4xø
45
/
64
"
8xø
45
/
64
"
8xø
55
/
64
"
4
21
/
64
"
4
59
/
64
"
6
19
/
64
"
9
29
/
64
"
3
15
/
16
"
3
11
/
32
"
4
17
/
32
"
5
33
/
64
"
5
29
/
32
"
6
1
/
2
"
7
7
/
8
"
11
7
/
32
"
45
/
64
"
45
/
64
"
45
/
64
"
25
/
32
"
15
/
16
"
55
/
64
"
DN PN
D
k
b
FA
25
40
EA
40
40
FB
50 40
d2
d4
f
FM 150 16
FE
80 40
FC
32
40
6
7
/
32
"
1
/
8
"
8xø
45
/
64
"
7
3
/
32
"
8
21
/
32
"
25
/
32
"
FK
100 16
7
1
/
2
"
1
1
/
4
"
1
/
8
"
4xø
5
/
8
"
6
6
3
5
/
8
"
6
3
/
16
"
1
/
8
"
4xø
5
/
8
"
4
3
/
4
"
7
7
/
8
"
3
/
4
"
3
/
4
"
1
/
8
"
8xø
5
/
8
"
6"
10"
"
lbs
D
b
k
d2
d4
f
FO
2" 150
FI
3" 150
EB
4" 300
7
1
/
2
"
1
1
/
4
"
1
/
8
"
4xø
5
/
8
"
6
6
3
5
/
8
"
6
3
/
16
"
1
/
8
"
4xø
5
/
8
"
4
3
/
4
"
7
7
/
8
"
3
/
4
"
3
/
4
"
1
/
8
"
8xø
5
/
8
"
6"
10"
"
lbs
D
b
k
d2
d4
f
FO
2" 150
FI
3" 150
EB
4" 300
51 mm (2
1
/
64
")
L
D
d4
k
ø 40 mm
(1
37
/
64
")
ø 8 mm
(
5
/
16
")
163 mm (6
27
/
64
")
d2
f b
Fig. 48: VEGABAR 67, flange connection
1 Flanges according to DIN 2501
2 Flanges according to ANSI B16.5
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)