T
his function enables reading out parameter adjustment data as well
as writing parameter adjustment data into the sensor via the indicating
and adjustment module. A description of the function is available in the
operating instructions manual "Indicating and adjustment module".
T
he following data are read out or written with this function:
l
M
easured value presentation
l
A
djustment
l
M
edium
l
I
nner diameter of the standpipe (with standpipe versions)
l
V
essel form
l
D
amping
l
L
inearisation curve
l
S
ensor-TAG
l
D
isplayed value
l
D
isplay unit
l
S
caling
l
C
urrent output
l
U
nit of measurement
l
L
anguage
T
he following safety-relevant data are not read out or written:
l
HART
mode
l
PIN
l
SIL
C
opy sensor data
C
opy sensor data?
Basic adjustment
I
f the "Reset" is carried out, the sensor resets the values of the
following functions to the reset values (see chart):
1)
Function
Reset value
M
ax. adjustment
0
m(d)
M
in. adjustment
15
m(d) (VEGAPULS 67)
70
m(d) (VEGAPULS 68)
M
edium
B
ulk solid
V
essel form
not known
D
amping
0
s
L
inearisation
linear
S
ensor-TAG
S
ensor
D
isplayed value
D
istance
E
xtended settings
N
one
1)
S
ensor-specific basic adjustment.
Copy sensor data
Reset
38
VEGAPULS
67 • 4 … 20
mA/HART two-wire
6 S
et up with the indicating and adjustment module PLICSCOM
32938
-EN
-100514