10 supplement, 1 technical data – VEGA VEGABAR 63 4 … 20 mA_HART User Manual
Page 55
10 Supplement
10.1 Technical data
General data
P
ressure type
G
auge pressure or gauge pressure
M
easuring principle
D
epending on the measuring range piezoresistive
with internal transmission liquid or strain gauge
(DMS)
dry.
C
ommunication interface
I
²C
bus
Materials and weights
M
aterials, wetted parts
-
P
rocess fitting
316T
i
-
D
iaphragm standard
316T
i
-
D
iaphragm from measuring range 25 bar,
with not flush version
E
lgiloy 2.4711
-
S
eal ring, O-ring
FKM (VP2/A), EPDM (A+P 75.5/KW75F), NBR
(COG), FFKM (C
hemraz 535)
M
aterials, non-wetted parts
-
I
nternal transmission liquid
S
ynthetic oil, Halocarbon oil
9)10)
-
E
lectronics housing
P
lastic PBT (polyester), Alu die-casting powder-
coated, 316L
-
E
xternal electronics housing
plastic PBT (Polyester)
-
S
ocket, wall mounting plate external
electronics housing
plastic PBT (Polyester)
-
S
eal between housing socket and wall
mounting plate
TPE (fi
xed connected)
-
S
eal ring, housing cover
NBR (
stainless steel housing), silicone (Alu/plastic
housing)
-
I
nspection window in housing cover for
indicating and adjustment module
P
olycarbonate (UL-746-C listed)
-
G
round terminal
316T
i/316L
-
C
onnection between IP 68 transmitter
and external electronics housing
PUR, FEP, PE
-
T
ype plate support with IP 68 version on
cable
PE
hard
W
eight approx.
0.8
kg (1.764 lbs)
9)
S
ynthetic oil for measuring ranges up to 16 bar, FDA listed for the food
processing industry. For measuring ranges up to 25 bar dry measuring cell.
10)
H
alocarbon oil: Generally in oxygen applications, not with vacuum meas-
uring ranges, not with absolute measuring ranges < 1 bar
abs
.
VEGABAR
63 • 4 … 20
mA/HART
55
10 S
upplement
32462
-
EN
-081209