beautypg.com

VEGA VEGACAP 65 - Relay (DPDT) User Manual

Page 31

background image

31

9 Supplement

VEGACAP 65 • - Relay (DPDT)

30016-EN-130916

Voltage supply
Operating voltage

20 … 253 V AC, 50/60 Hz, 20 … 72 V DC (at

U >60 V DC, the ambient temperature can be max.

50 °C/122 °F)

Power consumption

1 … 8 VA (AC), approximately 1 W (DC)

Electrical protective measures
Protection rating

IP 66/IP 67

Overvoltage category

III

Protection class

I

Functional safety (SIL)
Functional safety is already activated on instruments with SIL qualification ex factory. On instru-

ments without SIL qualification ex factory, the functional safety must be activated by the user via

the display and adjustment module or via PACTware for applications according to SIL.

Functional safety according to IEC 61508-4

Ʋ Single channel architecture (1oo1D) up to SIL2

Ʋ double channel diversitary redundant

architecture (1oo2D)

up to SIL3

You can find detailed information in the supplied Safety Manual of the instrument series or under

"www.vega.com", "Downloads", "Approvals".
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully

noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"

and "serial number search" as well as via "Downloads" and "Approvals".