background image

1000

750

500

250

15

18

16

20

22

24

26

28

30

32

34

36

V

4

1

2

3

Fig. 41: Voltage diagram

1

HART load

2

Voltage limit EEx-ia instrument

3

Voltage limit non-Ex/Exd instrument

4

Operating voltage

Electrical protective measures

P

rotection, depending on housing version

-

P

lastic housing

IP

66/IP 67

-

A

luminium housing, stainless steel

housing - investment casting, stainless
steel housing - electro-polished

IP

66/IP 68 (0.2

bar)

8)

-

A

luminium and stainless housing, in-

vestment casting (optionally available)

IP

66/IP 68 (1

bar)

O

vervoltage category

III

P

rotection class

II

Functional safety (SIL)

T

he functional safety is already activated ex factory for instruments with SIL qualification. For

instruments without SIL qualification ex factory, the functional safety must be activated by the user
via the indicating and adjustment module or via PACTware for applications according to SIL.

F

unctional safety according to IEC 61508-4

-

S

ingle channel architecture (1oo1D)

up to SIL2

-

double channel diversitary redundant
architecture (1oo2D)

up to SIL3

Y

ou can find detailed information in the supplied Safety Manual of the instrument series or under

"

www.vega.com", "Downloads", "Approvals".

8)

A

suitable cable is the prerequisite for maintaining the protection class.

VEGAPULS

68 • 4 … 20

mA/HART two-wire

63

10 S

upplement

29261

-EN

-090305