VEGA VEGAPULS 68 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART two-wire User Manual
Page 61
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
C
able entry/plug
7)
-
S
ingle chamber housing
l
1
x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5
or:
l
1
x closing cap M20 x 1.5; 1 x blind stopper
M
20
x 1.5
or:
l
1
x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1
x plug (depending on the version), 1 x blind
stopper M20 x 1.5
-
D
ouble chamber housing
l
1
x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5; 1 x blind stopper
M
16
x 1.5 or optionally available with 1 x plug
M
12
x 1 for VEGADIS 61
or:
l
1
x closing cap ½ NPT, 1 x blind stopper
½
NPT, 1
x blind stopper M16 x 1.5 or
optionally 1 x plug M12 x 1 for VEGADIS 61
or:
l
1
x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
VEGADIS
61
S
pring-loaded terminals for wire cross-sec-
tion
>
2.5
mm² (AWG 14)
Electromechanical data - version IP 66/IP 68 (1 bar)
C
able entry
-
S
ingle chamber housing
1
x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M
20
x 1.5
-
D
ouble chamber housing
1
x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M
20
x 1.5; 1 x blind stopper M16 x 1.5
C
onnection cable
-
W
ire cross-section
0.5
mm² (AWG 20)
-
W
ire resistance
<
0.036 Ω/
m
-
T
ensile strength
<
1200 N (270
lbf)
-
S
tandard length
5
m (16.4 ft)
-
M
ax. length
1000
m (3280 ft)
-
M
in. bending radius
25
mm (0.984 in) with 25 °C (77 °F)
7)
D
epending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
VEGAPULS
68 • 4 … 20
mA/HART two-wire
61
10 S
upplement
29261
-EN
-090305