VEGA VEGABAR 65 4 … 20 mA_HART User Manual
Page 59

-
with cooling element
-12 … +180 °C (+10 … +356 °F)
-
with cooling element and screening
sheet
-12 … +200 °C (+10 … +392 °F)
V
ibration resistance
mechanical vibrations with 4 g and 5 … 100 Hz
10)
S
hock resistance
A
cceleration 100 g/6 ms
11)
Electromechanical data - version IP 66/IP 67
C
able entry/plug
12)
-
S
ingle chamber housing
l
1
x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5
or:
l
1
x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1
x plug (depending on the version), 1 x blind
stopper M20 x 1.5
or:
l
2
x blind stopper M20 x 1,5
-
D
ouble chamber housing
l
1
x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS
61 (
optional)
or:
l
1
x closing cap ½ NPT, 1 x blind stopper
½ NPT,
plug M12 x 1 for VEGADIS 61
(
optional)
or:
l
1
x plug (depending on the version), 1 x blind
stopper M20 x 1.5; plug M12 x 1 for VEGADIS
61 (
optional)
or:
l
2
x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS
61 (
optional)
S
pring-loaded terminals for wire cross-sec-
tion
<
2.5
mm² (AWG 14)
10)
T
ested according to the regulations of German Lloyd, GL directive 2.
11)
T
ested according to EN 60068-2-27.
12)
D
epending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.
VEGABAR
65 • 4 … 20
mA/HART
59
10 S
upplement
27531
-
EN
-081209