VEGA VEGAPULS 66 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART four-wire User Manual
Page 51
Electromechanical data - version IP 66/IP 67
C
able entry
-
D
ouble chamber housing
l
1
x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1
x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS
61 (
optional)
or:
l
1
x closing cap ½ NPT, 1 x blind stopper
½
NPT,
plug M12 x 1 for VEGADIS 61
(
optional)
or:
l
1
x plug (depending on the version), 1 x blind
stopper M20 x 1.5; plug M12 x 1 for VEGADIS
61 (
optional)
S
pring-loaded terminals for wire cross-sec-
tion
2.5
mm² (AWG 14)
Indicating and adjustment module
V
oltage supply and data transmission
through the sensor
I
ndication
LC
display in dot matrix
A
djustment elements
4
keys
P
rotection
-
unassembled
IP
20
-
mounted into the sensor without cover
IP
40
M
aterials
-
H
ousing
ABS
-
I
nspection window
P
olyester foil
Power supply
O
perating voltage
-
N
on-Ex and Ex-d instrument
20 … 72 V DC, 20 … 253 V AC, 50/60 H
z
M
ax. power consumption
4 VA; 2.1 W
Electrical protective measures
P
rotection
IP
66/IP 67
O
vervoltage category
III
P
rotection class
I
Functional safety (SIL)
T
he functional safety is already activated ex factory for instruments with SIL qualification. For
instruments without SIL qualification ex factory, the functional safety must be activated by the user
via the indicating and adjustment module or via PACTware for applications according to SIL.
VEGAPULS
66 • 4 … 20
mA/HART four-wire
51
10 S
upplement
28443
-EN
-090305