ca. 10 mm

Fig. 9: Tube extension

Tip:
VEGAPULS

66

is optionally also available with antenna extension.

H

ence the antenna length can be selected such that the antenna end

protrudes 10 mm (0.4 in) out of the socket.

A

lign the sensor in liquids as vertical as possible to the product surface

to achieve optimum measurement.

Fig. 10: Alignment in liquids

T

he mounting location of the radar sensor should be a place where no

other equipment or fixtures cross the path of the microwave signals.

V

essel installations such as, for example, ladders, limit switches,

heating spirals, struts, etc. can cause false echoes that get super-
imposed on the useful echo. Make sure when planning your measuring
site that the radar sensor has a "clear view" to the measured product.

I

n case of existing vessel installations, a false echo storage should be

carried out during setup.