2 sensor vegaswing 83 w5 ex with oscillator e86 ex, 4 dimensional drawings, 1 vegaswing 83 w5 ex – VEGA VEGATROL 10 Ex 1 User Manual
Page 8
VEGATROL 10 Ex 1
8
2 Technical Information
2.3.2 Sensor VEGASWING 83 W5 Ex with oscillator E86 Ex
Supply and signal circuit
Power supply
12 … 18,9 V DC
(from signal conditioning instrument VEGATOR 526 W Ex)
Data transmission
analog, 4 … 20 mA
Flame proofing
EEx ia IIC, T4
Internal effective capacitance
C
int
unimportant
Internal effective inductance
L
int
unimportant
Power consumption
tuning fork uncovered
approx. 7 mA
tuning fork coverd
10 … 20 mA
Fault signal
approx. 25 mA
Reference value
approx. 15 mA
Connection line
2-wire
Ambient conditions
Permissible operating temperature
-30
°
C … +70
°
C
Storage and transport temperature
-40
°
C … +80
°
C
Operating pressure
max. 25 bar
however observe max. permissible pressure of the flange
Electrical connection
Terminals in plastic housing
for connection of max. 1,5 mm
2
Cable entry
Pg 13,5
Electrical protective measures
Protection
IP 67
Protection class
II
Mechanical data
Material
Mounting parts
stainless steel 1.4571
Extension tube
stainless steel 1.4571
Tuning fork
stainless steel 1.4581
Resonance frequency of the tuning fork in air
approx. 380 Hz
Dimensions
see dimensional drawing
2.4
Dimensional drawings
2.4.1 VEGASWING 83 W5 Ex
(approx. dimensions in mm)
80x110
75
39
25
approx. 30
Switch point
L (min. 200, max. 3000)