beautypg.com

9 supplement, 1 technical data – VEGA VEGATOR 636 Ex Ship approvals User Manual

Page 25

background image

25

9 Supplement

VEGATOR 636 Ex • Signal conditioning instrument

23446-EN-130627

9 Supplement

9.1 Technical data

General data
Series

Module unit with plug-in socket for mounting on carrier

rail 35 x 7.5 or 35 x 5 according to EN 50022

Weight

170 g (6 oz)

Housing material

Noryl SE100, Lexan 920A

Socket material

Noryl SE100, Noryl SE1 GFN3

Voltage supply
Operating voltage

20 … 250 V AC, 50/60 Hz, 20 … 72 V DC

Max. power consumption

3 W (3 … 18 VA)

Sensor input
Quantity

1

Data transmission

Analogue

Hysteresis

100 µA

Switching threshold

12 mA

Current limitation

24 mA (permanently short-circuit proof)

Sensor operating voltage

15 … 18 V DC

Detection line break

< 2.3 mA

Detection shortcircuit

> 23.2 mA

Configuration, connection cable

2-wire

Resistance per conductor

max. 35 Ω

Relay output
Number, function

1 x switching relay (spdt)

Switching delay

0.2 … 20 s, directional switching

Mode

A/B switch (A - max. detection or overfill protection, B -

min. detection or dry run protection)

Contact

1 x spdt

Contact material

AgNi 0.15 hard gold-plated

Switching voltage

≥ 10 mV DC, ≤ 253 V AC/DC

Switching current

≥ 10 µA DC, ≤ 3 A AC, 1 A DC

Breaking capacity

≤ 500 VA, ≤ 54 W DC

Transistor output
Number, function

1 output, synchronously switching with the relay

Galvanic separation

Floating

Maximum values

Ʋ U

B

36 V DC

Ʋ I

B

≤ 60 mA, short-circuit proof

Transistor voltage loss (U

CE

)

approx. 1.5 V at I

B