beautypg.com

VEGA VEGAWELL 72 4 … 20 mA_HART User Manual

Page 35

background image

-

P

lastic housing

0.8

kg (1.764 lbs)

-

S

tainless steel housing

1.6

kg (3.528 lbs)

Input variable

Adjustment

Z

ero adjustable

-20 … +95 %

of the nominal measuring range

S

pan adjustable

3.3 … +120 %

of the nominal measuring

range

R

ecommended max. turn down

10 : 1

Nominal measuring ranges and overload capability in bar/kPa

Nominal range

Overload, max. pressure Overload, min. pressure

G

auge pressure

0 … 0.1

bar/0 … 10 kPa

15

bar/1500 kPa

-0.2

bar/-20 kPa

0 … 0.2

bar/0 … 20 kPa

20

bar/2000 kPa

-0.4

bar/-40 kPa

0 … 0.4

bar/0 … 40 kPa

30

bar/3000 kPa

-0.8

bar/-80 kPa

0 … 1

bar/0 … 100 kPa

35

bar/3500 kPa

-1

bar/-100 kPa

0 … 2.5

bar/0 … 250 kPa

50

bar/5000 kPa

-1

bar/-100 kPa

0 … 5

bar/0 … 500 kPa

65

bar/6500 kPa

-1

bar/-100 kPa

0 … 10

bar/0 … 1000 kPa

90

bar/9000 kPa

-1

bar/-100 kPa

0 … 25

bar/0 … 2500 kPa

130

bar/13000 kPa

-1

bar/-100 kPa

A

bsolute pressure

0 … 1

bar/0 … 100 kPa

35

bar/3500 kPa

0

bar abs.

0 … 2.5

bar/0 … 250 kPa

50

bar/5000 kPa

0

bar abs.

0 … 5

bar/0 … 500 kPa

65

bar/6500 kPa

0

bar abs.

0 … 10

bar/0 … 1000 kPa

90

bar/9000 kPa

0

bar abs.

0 … 25

bar/0 … 2500 kPa

130

bar/13000 kPa

0

bar abs.

Nominal measuring ranges and overload capability in psig

Nominal range

Overload, max. pressure Overload, min. pressure

G

auge pressure

0 … 1.5

psig

200

psig

-3

psig

0 … 3

psig

290

psig

-6

psig

0 … 6

psig

430

psig

-12

psig

0 … 15

psig

500

psig

-15

psig

0 … 35

psig

700

psig

-15

psig

0 … 70

psig

950

psig

-15

psig

0 … 150

psig

1300

psig

-15

psig

0 … 350

psig

1900

psig

-15

psig

0 … 900

psig

2900

psig

-15

psig

VEGAWELL

72 • 4 … 20

mA/HART

35

10 S

upplement

27630

-

EN

-080806