2 principle of operation, 3 operation – VEGA VEGAPULS 65 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART four-wire User Manual
Page 10
W
ith the serial number, you can access the delivery data of the
instrument via www.vega.com, "VEGA Tools" and "serial number
search". In addition to the type label outside, you can also find the
serial number on the inside of the instrument.
3.2 Principle of operation
VEGAPULS
65
is a radar sensor in C-band technology (emitting
frequency approx. 6 GHz) for continuous level measurement. It is
particularly suitable for vessels with small process fitting that contain
corrosive liquids under simple to difficult process conditions.
T
he antenna of the radar sensor emits short radar pulses with a
duration of approx. 1 ns. These pulses are reflected by the product
and received by the antenna as echoes. The running time of the radar
pulses from emission to reception is proportional to the distance and
hence to the level. The determined level is converted into an
appropriate output signal and outputted as measured value.
F
our-wire electronics with separate power supply.
T
he supply voltage range can differ depending on the instrument
version.
T
he data for power supply are specified in chapter "Technical data".
M
easured value transmission is carried out via the 4 … 20 mA/HART
output separate from power supply.
T
he background lighting of the indicating and adjustment module is
powered by the sensor. A certain level of operating voltage is required
for this. You can find the exact voltage specifications in chapter
"
Technical data".
3.3 Operation
VEGAPULS
65
can be adjusted with different adjustment media:
l
with indicating and adjustment module
l
with the suitable VEGA DTM in conjunction with an adjustment
software according to the FDT/DTM standard, e.g. PACTware and
PC
l
with manufacturer-specific adjustment programs AMS™ or PDM
l
W
ith a HART handheld
T
he entered parameters are generally saved in VEGAPULS 65,
optionally also in the indicating and adjustment module or in
PACT
ware.
Application area
Functional principle
Power supply
10
VEGAPULS
65 • 4 … 20
mA/HART four-wire
3 P
roduct description
28442
-EN
-090305