SUUNTO D6 User Manual
Page 88
Displays only in NITROX mode:
•
Oxygen %: 21 - 99
•
Oxygen partial pressure display: 0.2 - 3.0 bar, depending on the limit setting
•
Oxygen Limit Fraction: 1 - 200% with 1% resolution
Logbook/dive profile memory:
•
Recording interval: 20 seconds adjustable (1,10,20,30,60s). Records the maximum
depth and minimum temperature of each interval
•
Memory capacity: approximately 36 hours of diving with 20 second recording
interval
•
Depth accuracy: 0.3 m/1 ft
Operating conditions:
•
Normal altitude range: 0 to 3,000 m/10,000 ft above sea level
•
Operating temperature: 0°C to 40°C/32°F to 104°F
•
Storage temperature: -20°C to +50°C/ -4°F to +122°F
It is recommended that the instrument be stored in a dry place at room temperature.
NOTE
Do not leave the dive computer in direct sunlight!
Tissue calculation model:
•
Suunto Deep Stop RGBM algorithm (developed by Suunto and Bruce R. Wienke,
BSc, MSc, PhD)
•
9 tissue compartments
•
Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes
(on gassing). The off gassing halftimes are slowed down
88