beautypg.com

Parts and functions 2. unit mounting – V-Tech C5-IPC Info User Manual

Page 2

background image

1. Parts and Functions

2. Unit Mounting

109mm

124mm

Direct Wall Mounting

DIN Rail Mounting

JWB(IN)

S1

RS485

POWER

JWB(OUT)

CN(MDS) ETHERNET

JTAG

POWER

PA

IN-USE

LINK

VR600

JP1/2/3 SW1

*

PA: Reset button. Press and hold for 3s to
initialize C5-IPC; If initialization complete
successfully, power off, and re-power C5-
IPC, LINK&IN-USE indicators will flicker
once simultaneously, then INK indicator will
flicker till IN-USE indicator is always ON

*

S1: DIP Switch. Refer to DIP Switch Setting

*

JTAG: PC Port. Update C5-IPC program by
PC that is connected by RS232 convertor

*

RS485: PC Port. Set parameters update
the firmware of C5-IPC by PC RS485-USB
convertor

*

JWP: Power Input P+: Positive,18V; P-:
Negative

*

JWB (IN): Bus Signal Input. RJ45 port includes audio, data & video. It can be connected to door
station only

*

JWB (OUT): Bus Signal Output. RJ45 port includes audio, data & video. It can be connected to
distributor.

*

CN-MDS: Bus Signal Input. RJ45 port,connected to MDS only

*

CN-NET: RJ45 Network Port, connected to LAN

*

JP1/JP2/JP3: Jumper. Removed if C5-MDS connected

*

SWI: Distributor Setting. Match different distributor