V-Tech PC6 Manual User Manual
Pc6 power comb instructions, Introduction, Terminal description: 4. wiring
1. Introduction:
The PC6 is a power comb unit,which is designed for DT 2
wire system to supply power for outdoor station, indoor
monitor and other accessories. It can work both as a nor-
mal power comb and auxiliary power comb. The features
are as follows:
• Universal AC input/full range
• Multi protection: short circuit, overload, over voltage
• Integrated with DT-DPS(power separator), Additional
DT-DPS is not needed.
• Support up to 4~8 monitors(depend on models)
• DIN rail mounting
2. Terminal Description:
4. Wiring:
Open the AC cover:
1. push the cover bottom
towards the center with
your hand;
2. turn over and pull it out.
After connect the AC cable,
it is suggested to close the cover.
PC6 Power Comb Instructions
5. Specification:
Input Voltage:
100~240Vac
Input Frequency:
50~60Hz
Rated Output Voltage:
DC 28V+2V
Rated Output Current:
1.5A
Working Temperature:
-10
0
C~50
0
C
SW Port Input Voltage:
Max.230Vac, 2A
Dimension:
140*90*60mm
3. Mounting:
Step1: Mount the din rail to the wall with screws ;
Step2: Pull down the mounting buckle,then hang the
unit on din rail.
N: AC input.
L: AC input.
SW: switch terminal. It can extend to connect light or
lock.
LED: power indicator,always on when plug in power.
CN2: normal power comb or auxiliary power comb se-
lection terminal. Please refer to part 4.
CN1: bus control terminal.
BUS(IM): indoor monitor connection terminal.
BUS(DS): door station connection terminal.
Note:
1. the AC cable is not included in the package, it must
comply with requirements of different country.
2. If N,SW terminal is connected light or lock, CN1
terminal must connect SC6 controller to support this
function.
3. pin1&2 should be short-circuited with a C3-3P
line(included in the package) if the unit work as a nor-
mal power comb. But if it work as a auxiliary power
comb, pin 1&2 should be taken off.
6. Warning:
- The unit can only be used in DT 2 wire products sup-
plied by our company.
- Don’t connect the unit with any non-specified power
source. Fire or electric shock could result.
- Don’t dismantle or alter the unit. Fire or electric shock
could result.
- The unit must be installed and wired by a qualified
technician.
- Keep the unit away from water or any other liquid. Fire
or electric shock could result.
We reserve the right to modify the specification in this manual at any time without notice.
Din rail
Din rail
Mounting Buckle
N N
L SW
LED
CN1
CN2
1 2 3
BUS(IM) BUS(DS)
N N L SW
AC~
connect to light/lock
CN1
CN2
1 2 3
BUS(IM)
Connect to monitor
Connect to door staiton
BUS(DS)