Veris Technologies pH Manager - Field Reference Guide User Manual
Page 2

6. Raise sampling shoe
—check for ¼” to ½” clearance
between electrodes and trough; make sure this is where
the shoe will stop in automatic mode (see prox sensor
adjustment section in Operating Instructions)
7. Operate wash jets and check alignment; does water
bubble out of top when electrodes are removed?
8. Raise unit and drive slowly in semi-circle with unit cycling
to check automated functions
9. Calibrate electrodes
Insert electrodes into holder and finger-
tighten set screws. Follow menu
prompts to “pH Setup”. The instrument
will prompt for the electrodes to be
inserted into pH buffer 4 solution; Slide
pH 4 buffer solution container onto
electrode holder. Press 1 to continue
with calibration or 2 to exit. Repeat with
pH 7 buffer solution.