Ordering information – Veris Verabar V110 Spec Sheet User Manual
Page 3
Model
Regular
V100
Compression Fitting (Single Support)
V110
Compression Fitting (Double Support)
Pipe Size and Schedule or Exact ID and Wall Thickness
Code Sensor Pipe Size Range
05
2” to 6” (50mm to 150mm)
10
6” to 48” (150mm to 1200mm)
Code Pipe Orientation
H
Horizontal
V
Vertical
Instrument Connections
(Select Remote or Direct Mount)
(Transmitter sold separately)
Remote Mount Transmitter
Direct Mount Transmitter
(1/2” NPT)
(Flanged 450°F/232°C Max.)†
Parallel
Regular
RTD
*
Valve
Transmount
Mass Transmount
*
Manifold
P
R
D
T
F
G
E
M
Code
Options
For stainless steel pipes.
WNS
For V100, furnished with one SS weld coupling.
For V110, furnished with two SS weld couplings and
one SS plug.
V100
8”sch 40
10
H
R
C2NC
Typical Model Number
Ordering Information
*
For high pressure (>500psig) or high temperature (>500°F), remote mount RTD in a thermowell is preferred.
† Assuming adequate heat dissipation for transmitter.
Instrument Valves
(Opt.)
Manifolds
(Optional)
Remote Mount
Direct Mount
Needle
Gate
3-Valve
5-Valve
C2NC (CS)
C2GC (CS)
F3SC (CS)
F3HC (CS)
F5SC (CS)
F5HC(CS)
C2NS (SS)
C2GS (SS)
F3SS (SS)
F3HS (SS)
F5SS (SS)
F5HS (SS)
1/2” NPT
Soft Seat
Hard Seat
Soft Seat
Hard Seat
1/2” NPT
Explsn. Proof
Remote
RTD
Integral
RTD
Integral
Integral
Optional