Efficiency = 92.5, Efficiency = 91.5, 6 lamp, t8 fluorescent high bay photometrics – Oracle Lighting CB-4 User Manual
Page 8: 4 lamp, t8 fluorescent high bay photometrics
75
www.oraclelighting.com • tel: 1-877-375-5555 • FaX: 1-877-375-3333
6 LAMP, T8 FLUORESCENT HIGH BAY PHOTOMETRICS
CB-6-32-T8
LAMP:
PHILIPS F32T8/TL24/PLUS/ALTO LAMP LUMENS: 2950 TOTAL LUMINAIRE EFFICIENCY: 92.5%
SPACING CRITERIA:
1.16
Coefficients of Utilization - zonal Cavity Method (Effective Floor Cavity Reflectance 0.20)
0
90
180
30
ACROSS
45
ALONG
150
60
120
1585
4756
6341
RO
O
M
C
AV
IT
Y
RA
TI
O
RC
80%
70%
50%
30%
10%
0%
RW
70% 50% 30% 10%
70% 50% 30% 10%
50% 30% 10%
50% 30% 10%
50% 30% 10%
0%
0
100 100 100 100
98 98 98 98
93 93 93
89
89
89
86 86
86
84
1
91 87 83 80
89 85 82 78
81 79 76
78 76 74
75 73 71
70
2
83 76 70 65
80 74 69 64
71 66 63
68 64 61
66 63 60
58
3
76 67 60 54
73 65 59 54
63 57 53
60 56 52
58 54 51
49
4
69 59 52 46
67 58 51 46
56 50 45
54 49 44
52 48 44
42
5
64 53 45 40
62 52 45 40
50 44 39
49 43 39
47 42 38
36
6
59 48 40 35
57 47 40 35
46 39 34
44 38 34
43 38 34
32
7
55 44 36 31
53 43 36 31
42 35 31
40 35 30
39 34 30
29
8
51 40 33 28
50 39 32 28
38 32 28
37 31 27
36 31 27
26
9
48 37 30 25
47 36 30 25
35 29 25
34 29 25
33 28 25
23
10
45 34 27 23
44 33 27 23
33 27 23
32 26 23
31 26 23
21
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
110
100
91
83
76
70
65
60
56
53
49
110
96
83
73
65
58
53
48
44
40
37
110
91
77
66
57
50
44
40
36
33
30
110
88
71
59
51
44
38
34
31
28
25
108
98
89
81
74
68
63
59
55
51
48
108
93
81
72
64
57
52
47
43
40
37
108
90
76
65
56
49
44
39
36
33
30
92
77
65
55
48
42
37
33
30
27
25
103
89
78
69
61
55
50
46
42
39
36
103
86
73
63
55
48
43
39
35
32
29
103
84
69
58
49
43
38
34
30
27
25
98
86
75
66
59
53
48
44
41
38
35
98
83
71
61
53
47
42
38
35
32
29
98
81
67
57
49
43
38
33
30
27
25
94
82
72
64
57
52
47
43
40
37
34
94
80
69
60
52
46
42
37
34
31
29
94
79
66
56
48
42
37
33
30
27
25
92
77
64
54
46
40
35
31
28
25
23
0
22.5
45
67.5
90
0
6328.05
6328.05
6328.05
6328.05
6328.05
5
6302.7
6314.94
6326.3
6314.5
6278.44
15
6109.82
6098.6
5737.17
5187.45
4964.7
25
5676.57
5435.25
4218.38
3939.33
3959.15
35
4950.86
4168.41
3560.49
3725.04
3742.59
45
4014.87
2915.86
3134.01
3392.96
3366.01
55
3029.93
2257.09
2614.15
2431.47
2318.5
65
1940.31
1613.26
1585.58
1644.95
1762.51
75
874.95
817.7
1175.42
1524.69
1608.02
85
104.31
347.37
449.64
425.68
388.31
90
0
0
0
0
0
CANDELA TABULATION
6961
6933
6721
6244
5446
4416
3333
2134
962
115
0
6961
6946
6708
5979
4585
3207
2483
1775
899
382
0
6961
6959
6311
4640
3917
3447
2876
1744
1293
495
0
6961
6946
5706
4333
4098
3732
2675
1809
1677
468
0
6961
6906
5461
4355
4117
3703
2550
1939
1769
427
0
EFFICIENCY =
92.5%
T8 FLUORESCENT HIGH BAY
zONE
LUMENS
%LAMP
%FIxT
0-30
5909.6
24.3
28.9
0-40
9307.6
38.3
45.5
0-60
17842.31
65.2
77.5
60-90
20439.92
84.1
100
O-90
20439.92
84.1
100
zONAL LUMENS SUMMARY
TOTAL LUMINIARE EFFICIENCY =
92.5%
4,731.80
7,453.60
12,688.20
3,683.20
16,371.40
26.70%
42.10%
71.70%
20.80%
92.50%
28.90%
45.50%
77.50%
22.50%
100%
4 LAMP, T8 FLUORESCENT HIGH BAY PHOTOMETRICS
CB-4-32-T8
LAMP:
PHILIPS F32T8/TL24/PLUS/ALTO LAMP LUMENS: 2950 TOTAL LUMINAIRE EFFICIENCY: 91.5%
SPACING CRITERIA:
1.10
Coefficients of Utilization - zonal Cavity Method (Effective Floor Cavity Reflectance 0.20)
0
90
180
30
ACROSS
45
ALONG
150
60
120
1215
3646
4861
RO
O
M
C
AV
IT
Y
RA
TI
O
RC
80%
70%
50%
30%
10%
0%
RW
70% 50% 30% 10%
70% 50% 30% 10%
50% 30% 10%
50% 30% 10%
50% 30% 10%
0%
0
100 100 100 100
98 98 98 98
93 93 93
89
89
89
86 86
86
84
1
91 87 83 80
89 85 82 78
81 79 76
78 76 74
75 73 71
70
2
83 76 70 65
80 74 69 64
71 66 63
68 64 61
66 63 60
58
3
76 67 60 54
73 65 59 54
63 57 53
60 56 52
58 54 51
49
4
69 59 52 46
67 58 51 46
56 50 45
54 49 44
52 48 44
42
5
64 53 45 40
62 52 45 40
50 44 39
49 43 39
47 42 38
36
6
59 48 40 35
57 47 40 35
46 39 34
44 38 34
43 38 34
32
7
55 44 36 31
53 43 36 31
42 35 31
40 35 30
39 34 30
29
8
51 40 33 28
50 39 32 28
38 32 28
37 31 27
36 31 27
26
9
48 37 30 25
47 36 30 25
35 29 25
34 29 25
33 28 25
23
10
45 34 27 23
44 33 27 23
33 27 23
32 26 23
31 26 23
21
RC - Ceiling Cavity Reflectance RW - Wall Reflectance
109
99
90
82
76
70
64
60
56
52
49
109
95
83
73
65
58
52
48
44
40
37
109
91
76
65
57
50
44
40
36
33
30
109
87
71
59
50
44
38
34
30
28
25
106
97
88
80
74
68
63
58
54
51
48
106
93
81
71
63
57
51
47
43
40
37
106
89
75
64
56
49
44
39
36
32
30
106
86
70
59
50
43
38
34
30
27
25
102
89
78
69
61
55
50
45
42
38
36
102
86
73
63
55
48
43
39
35
32
29
102
83
69
58
49
43
38
34
30
27
25
97
85
75
66
59
53
48
44
41
37
35
97
83
71
61
53
47
42
38
34
32
29
97
81
67
57
49
42
37
33
30
27
25
93
82
72
64
57
51
47
43
39
37
34
93
80
69
59
52
46
41
37
34
31
29
93
78
66
56
48
42
37
33
30
27
25
92
76
64
54
46
40
35
31
28
25
23
0
22.5
45
67.5
90
0
6328.05
6328.05
6328.05
6328.05
6328.05
5
6302.7
6314.94
6326.3
6314.5
6278.44
15
6109.82
6098.6
5737.17
5187.45
4964.7
25
5676.57
5435.25
4218.38
3939.33
3959.15
35
4950.86
4168.41
3560.49
3725.04
3742.59
45
4014.87
2915.86
3134.01
3392.96
3366.01
55
3029.93
2257.09
2614.15
2431.47
2318.5
65
1940.31
1613.26
1585.58
1644.95
1762.51
75
874.95
817.7
1175.42
1524.69
1608.02
85
104.31
347.37
449.64
425.68
388.31
90
0
0
0
0
0
CANDELA TABULATION
4855.44
4847.43
4656.32
4247.77
3639.13
2968.39
2221.46
1376.02
590.74
66.3
0
4855.44
4829.82
4536.17
3884.23
2842.46
2022.35
1589.74
1208.15
589.32
219.33
0
4855.44
4802.4
4135.78
2965.17
2480.5
2388.05
2034.03
1141.77
803.41
240.69
0
4855.44
4764.42
3648.04
2782.31
2849.8
2690.39
1903.32
1129.94
1034.5
195.82
0
4855.44
4732.73
3463.38
2799.98
2927.85
2715.56
1773.34
1215.27
1068.81
168.62
0
EFFICIENCY =
91.5%
T8 FLUORESCENT HIGH BAY
zONE
LUMENS
%LAMP
%FIxT
0-30
5909.6
24.3
28.9
0-40
9307.6
38.3
45.5
0-60
17842.31
65.2
77.5
60-90
20439.92
84.1
100
O-90
20439.92
84.1
100
zONAL LUMENS SUMMARY
TOTAL LUMINIARE EFFICIENCY =
91.5%
3122.26
4914.42
8492.39
2305.00
10797.87
26.5
41.6
72
19.5
91.5
28.9
45.5
78.6
21.4