Ordering information, Oedi, Catalog number – Oracle Lighting OEDI-22 User Manual
Page 2: Project name type
Ordering Information
eXamPle: 24-oEDi-3-32-t8
FIxTURE SIzE
24 - 2’ x 4’
24
LAMPS INSTALLED
(
Blank)
L30K
L35K
L41K
L50K
- No lamps
- 3000K
- 3500K
- 4100K
- 5000K
-1 Ballast
-2 Ballasts
(
Blank)
2
# OF BALLAST
MAS1-Master fixture w/ 1
ballast & 11 ft. flex
MAS2-Master fixture w/ 2
ballast & 11 ft. flex
SAT-Satellite fixture w/o ballast
*must be ordered separately
Ex: 24-OSDI-2-32-T8-MAS2
and 24-OSDI-2-32-T8-SAT
*MASTER/SATELLITE
# LAMPS/LAMP TYPE
1-32-T8
2-32-T8
3-32-T8
(1 lamp/32W/T8)
(2 lamps/32W/T8)
(3 lamps/32W/T8)
(For other lamp type, please consult factory)
TRIM TYPE
(
Blank)-Grid
(Consult factory for
Slot T mounting option)
(Blank)
HBF
LBF
BALLAST FACTOR
1-28-T5
2-28-T5
3-28-T5
1-54-T5HO
2-54-T5HO
(1 lamp/28W/T5)
(2 lamps/28W/T5)
(3 lamps/28W/T5)
(1 lamp/54W/T5HO)
(2 lamps/54W/T5HO)
(
Blank)
120
277
347
- MVOLT (120/277)
VOLTAGE
2
- Normal BF
- High BF
- Low BF
EMERGENCY BATTERY PACK OPTIONS (L. = LUMENS)
ORDER CODE
DESCRIPTION
EMG-T8-Bx-450
Up to 450 L. for
T8 or Bx
EMG-T8-Bx-600
Up to 600 L. for
T8 or Bx
EMG-T8-Bx-700
Up to 700 L. for
T8 or Bx
EMG-T8-Bx-1400
Up to 1400 L. for
T8 or Bx
EMG-T5-520
Up to 520 L. for
T5
EMG-T5-T5HO-700
Up to 700 L. for
T5 or T5HO
EMG-T5-T5HO-1300
Up to 1300 L. for
T5 or T5HO
EMG-T8-Bx-T5-T5HO-3200
Up to 3200 L. for
T8, Bx, T5 or T5HO
EMG-SD-T8-Bx-T5-T5HO-1400
Self-Diagnostic 1400 L. for
T8, Bx, T5 or T5HO
EMG-ICE-T8-Bx-T5-T5HO-1400
ICE Pack 1400 L. for
T8, Bx, T5 or T5HO
MANY OTHER
BODINE AND IOTA EMERGENCY PACKS ARE AVAILABLE, PLEASE CONSULT FACTORY.
VISIT WWW.BODINE.COM OR WWW.IOTAENGINEERING.COM FOR MORE DETAILS.
BALLAST CONFIGURATION & CODE
32W/T8 28W/T5
54W/T5HO DESCRIPTION
(Blank)
-
-
Electronic Instant Start
EPS
(Blank)
1
(Blank)
Electronic Program Start
ADV-7
-
ADV-7
1
Advance Mark-7
2
ADV-10
-
ADV-10
1
Advance Mark-10
2
-
ADV-OPT
-
Advance Optanium
2
ADV-ESS
-
-
Advance Essential
2
ADV-ROVR
-
ADV-ROVR Advance Rover
2
LUT-EHD LUT-EHD
1
LUT-EHD
1
Lutron Ecosystem H-Series
2
LUT-2W
1
-
-
Lutron Tu-Wire
2
LUT-EC5 LUT-EC5
1
-
Lutron Ecosystem
2
LUT-EC3 LUT-EC3
1
LUT-EC3
1
Lutron Eco-10
2
LUT-TVE
1
-
-
Lutron Tve
2
LUT-H3D LUT-H3D
1
LUT-H3D
Lutron Hi-Lume 3D
2
-
-
LUT-ECD
1
Lutron Ecosystem (347V Only)
2
1- Requires 2 Ballasts for 3 lamps
2- Voltage must be specified for dimming ballast.
OTHER OPTIONS
24FK - Flange Kit for 2’ x 4’ Fixture
SBF - Internal Slow-Blow Fuse
C3 - 6’ 3-wire Flex Cable (Single Circuit)
RIS - Radio Interference Suppressor
C4 - 6’ 4-wire Flex Cable (Double Circuit)
DCR - Dust Cover
FBF - Internal Fast Blow Fuse
USA - Made in America Compliance
SERIES
OSDI
OEDI
OCDI
ONDI
Silhouette
Eclipse
Celest
Nova
37
www.oraclelighting.com • tel: 1-877-375-5555 • FaX: 1-877-375-3333
Flu
ore
sc
en
t r
ec
es
se
d
D
ire
ct
/in
dire
ct
S
ign
atu
re
S
er
ie
s
OEDI
Catalog Number
24-OEDI
Project Name
Type