Oracle Lighting OSL-4 User Manual
T8/t5 fluorescent stairwell with compact sensor, Fluor escent w all stairw ell ordering information, Catalog number
181
WWW.ORACLELIGHTING.COM • TEL: 1-877-375-5555 • FAX: 1-877-375-3333
T8/T5 FLUORESCENT STAIRWELL WITH COMPACT SENSOR
INTENDED USE:
• Ideal for Stairways, corridors, utility rooms and other low
occupancy applications.
• For use in residential, commercial and hospitality markets. For wall
or vanity application.
• Fixture is designed for optional up/ down directional lighting. Baffle
front cover plate is also removable for 180
0
illumination.
PRODUCT FEATURES:
• Motion sensor option allows for bi-level lighting and is built into the
fixture for a clean look.
• Comes standard with Muti-Volt Ballast.
• Available in white smooth or clear prismatic diffuser and white end
caps.
• Individually boxed.
• Diffuser easily removed via locking nut at both ends of fixture.
• Post-painted body and hemmed edges allow for safe handling and
installation.
OPTIONAL FEATURES:
• Dividers for up/down light.
• Front Baffle cover available for light block
LISTING - UL/ C-UL listed for damp locations.
WARRANTY - Guaranteed for one year against mechanical defects.
Fluor
escent
W
all
Stairw
ell
Ordering Information
EXAMPLE: 4-OSL-2-32W-T8
OSL
SERIES
OSL
WATTAGE
-1 Ballast
-2 Ballasts
(
Blank)
2
# OF BALLAST
(Blank)
HBF
LBF
BALLAST FACTOR
VOLTAGE
1
- Normal BF
- High BF
- Low BF
FIxTURE SIzE
4 - 4’
T8/T5
OSL
(
Blank)
120
277
- MVOLT (120/277)
48-1/4”
4-3/8”
4-1/2”
SPECIFICATIONS
TIME DELAY ADjUSTMENT
5, 10, 15 OR 30 MINUTES
TEST MODE
5 SECOND TIME DELAY FOR 5 MINUTES
OSLMS-FS-8 505 COVERAGE@ 8’ HEIGHT AT 20° ANGLE FROM VERTICAL 24’ MIN. LINEAR, 6’ MIN. AT 90° ON EACH SIDE
OSLMS-FS-10 505C COVERAGE@ 10’ HEIGHT PARALLEL TO FLOOR
12’ MIN. RADIUS FROM CENTER
OPERATING TEMPERATURE
32° TO 131°F (0° TO 55°C)
OSL-Oracle
Stairwell
WIRING OPTIONS
FBF - Internal Fast Blow Fuse
SBF - Internal Slow-Blow Fuse
RIS - Radio Interference Suppressor
OTHER OPTIONS
OSLMS-FS-8 - Motion Sensor 24’ MIN. LINEAR, 6’ MIN. AT 90° ON EACH SIDE
OSLMS-FS-10 - Motion Sensor 2’ MIN. RADIUS FROM CENTER
USA - Made in America Compliance
(1 lamp/32W/T8)/(1lamp/17W/T8)
(2 lamp/32W/T8)
(2 lamp/28W/T5)
(2 lamp/54W/T5HO)
1-32-T8
1
/1-17-T8
2
2-32-T8
2-28-T5
2-54-T5HO
BALLAST CONFIGURATION & CODE
32W/T8 28W/T5
54W/T5HO DESCRIPTION
(Blank)
-
-
Electronic Instant Start
1
EPS
(Blank)
(Blank) Electronic Program Start
1
1- Voltage must be specified for dimming ballast.
DESCRIPTION AND OPERATION
•
The OSLMS-FS-8 and OSLMS-FS-10 occupancy
sensors turn lighting on and off based on occupancy.
The sensors use ultrasonic sensing technology. Once
the space is vacant and the time delay elapses
(adjustable from 5 to 30 minutes), lights will turn off.
APPLICATION
•
For a large rectangular detection area with ceiling
mounted fixtures, the OSLMS-FS-10 provides
excellent coverage. For specialized applications such
as stairwells, the elongated coverage pattern of the
OSLMS-FS-8 is ideal.
•
The FS-505 can provide bi-level lighting control
in fixtures that have bi-level or dimming ballasts,
resulting in up to 66% energy savings for fixtures that
are on 24-hours a day, seven days a week, while still
providing enough light for safety and egress.
EMERGENCY BATTERY PACK OPTIONS (L. = LUMENS)
ORDER CODE
DESCRIPTION
EMG-T8-Bx-450
Up to 450 L. for
T8 or Bx
EMG-T8-Bx-600
Up to 600 L. for
T8 or Bx
EMG-T8-Bx-700
Up to 700 L. for
T8 or Bx
EMG-T8-Bx-1400
Up to 1400 L. for
T8 or Bx
EMG-T5-520
Up to 520 L. for
T5
EMG-T5-T5HO-700
Up to 700 L. for
T5 or T5HO
EMG-T5-T5HO-1300
Up to 1300 L. for
T5 or T5HO
EMG-T8-Bx-T5-T5HO-3200
Up to 3200 L. for
T8, Bx, T5 or T5HO
EMG-SD-T8-Bx-T5-T5HO-1400
Self-Diagnostic 1400 L. for
T8, Bx, T5 or T5HO
EMG-ICE-T8-Bx-T5-T5HO-1400
ICE Pack 1400 L. for
T8, Bx, T5 or T5HO
NOTE- 1 lamp on constantly
1
/1 lamp seasoner 2
2
Catalog Number
-OSL
Project Name
Type